![Teknim PARS Series Quick Installation Manual Download Page 9](http://html.mh-extra.com/html/teknim/pars-series/pars-series_quick-installation-manual_1076808009.webp)
8
T
EKNİM PARS SERIES
ALARM CONTROL PANELS
QUICK INSTALLATION GUIDE
4.
PROGRAMMING TABLE
This table shows all the settings, options, and factory settings available in the control panel.
<InC>
Access to Installer Menu with
“
Installer Code
”
–
Factory Default:
9999
<MaC>
Access to Master Menu with
“
Master Code
”
–
Factory Default:
1234
ADRESS
FUNCTION
VALUE-SETTINGS
FACTORTY
DEFAULT
ACCESS
AUTHORITY
0
–
BASIC SETTINGS
01
–
CLOCK SETTINGS
01 01
Time
HH: MM
HH:
Hour,
MM:
Minute
00:00
InC & MaC
01 02
Date
DD MM YY
DD:
Day,
MM:
Month,
YY:
Year (Last Two Digit)
00.00.00
InC & MaC
02
–
ENTRANCE DELAYS
02 01
02 02
02 03
02 04
A PART ENT DLY
B PART ENT DLY
C PART ENT DLY
D PART ENT DLY
0~255 Sec
15
0
0
0
InC
03
–
EXIT DELAYS
03 01
03 02
03 03
03 04
A PART EXT DLY
B PART EXT DLY
C PART EXT DLY
D PART EXT DLY
0~255 Sec
15
0
0
0
InC
04
–
CMS ACCOUNTS
04 01
04 02
1. CMS ACCNT NO
2. CMS ACCNT NO
4-digit account number
0000
0000
InC & MaC
05
–
CMS PHONES
05 01
05 02
05 03
05 04
1. CMS PHONE NO
2. CMS PHONE NO
3. CMS PHONE NO
4. CMS PHONE NO
Maximum 15-digit phone number
0 (press long) can give you space if you need time to wait for
line.
To erase the phone number press and hold
[B]
Empty
Empty
Empty
Empty
InC & MaC
06
–
PRIVATE PHONES
06 01
06 02
06 03
06 04
06 05
06 06
1. Phone Number
2. Phone Number
3. Phone Number
4. Phone Number
5. Phone Number
6. Phone Number
Maximum 15-digit phone number
0 (press long) can give you space if you need time to wait for
line.
To erase the phone number press and hold
[B]
Empty
Empty
Empty
Empty
Empty
Empty
InC & MaC
07
–
USER CODES
07 01
07 02
07 03
07 04
07 05
07 06
07 07
07 08
07 09
07 10
07 11
1. User Code
2. User Code
3. User Code
4. User Code
5. User Code
6. User Code
7. User Code
8. User Code
9. User Code
10. User Code
11. Threat (Duress) Code
4-digit code
----
----
----
----
----
----
----
----
----
----
MaC
1
–
PANEL SETTINGS
10
–
GENERAL SETTINGS
10 01
Panel Options
2. Quick Arm Enable / Disable
3. Auto Siren Test Enable / Disable
4. Arm / Disarm from Foreign Keypad Enable / Disable
5. Extend Exit Delay Enable / Disable
6. Double Hit Enable / Disable
2 - 5
InC
10 02
Output
1. PGM NC/NO
(On: NC, Off: NO)
4. SRN NC/NO (+/- Trigger)
1. NO
4. NO
InC