Teknim PARS Series Quick Installation Manual Download Page 1

 

 

 

V1.1 

Release Date: 26.12.2019 

PARS SERIES  

Alarm Control Panels 

TEKNİM PARS

 SERIES INTRUDER ALARM SYSTEMS QUICK 

INSTALLATION GUIDE 

Summary of Contents for PARS Series

Page 1: ...V1 1 Release Date 26 12 2019 PARS SERIES Alarm Control Panels TEKNİM PARS SERIES INTRUDER ALARM SYSTEMS QUICK INSTALLATION GUIDE ...

Page 2: ...ION DIAGRAMS 2 3 QUICK START GUIDE 5 Entering Installer Menu 5 Setting the Time 5 Setting the Date 5 Setting Entrance Delay 5 Setting Exit Delay 5 Setting CMS Account Number 5 Setting the CMS Phone Numbers 6 Setting the Backup CMS Phone Numbers 6 Setting the Private Phone Numbers 6 Password Settings 6 User Codes 7 4 PROGRAMMING TABLE 8 ...

Page 3: ...TALLATION GUIDE 2 TSP ALARM PANELS CONNECTION DIAGRAMS Warning Installation and electrical connections of the panel must be done by trained personnel Unconscious interventions may result in electrical current exposure and malfunctions of the panel board ...

Page 4: ...OL PANELS QUICK INSTALLATION GUIDE Warning Installation and electrical connections of the panel must be done by trained personnel Unconscious interventions may result in electrical current exposure and malfunctions of the panel board ...

Page 5: ...OL PANELS QUICK INSTALLATION GUIDE Warning Installation and electrical connections of the panel must be done by trained personnel Unconscious interventions may result in electrical current exposure and malfunctions of the panel board ...

Page 6: ... Basic Settings Ok Time Date Settings Ok Date DD MM YY Ok e To configure the date at 10 11 2019 01 02 10 11 19 Ok Setting Entrance Delay LED Keypad 02 01 Entrance Delay SS Ok LCD Keypad Basic Settings Ok Entrance Delay Ok 01 Part Ent Delay SS Ok e To configure the entrance delay 10sec 02 01 10 Ok Setting Exit Delay LED Keypad 03 01 Exit Delay SS Ok LCD Keypad Basic Settings Ok Exit Delays Ok 01 Pa...

Page 7: ... Number 06 03 Phone NO XXXXXXXXXXX Ok 4 User Phone Number 06 04 Phone NO XXXXXXXXXXX Ok 5 User Phone Number 06 05 Phone NO XXXXXXXXXXX Ok 6 User Phone Number 06 06 Phone NO XXXXXXXXXXX Ok LCD Keypad Basic Settings Ok Private Phones Ok XXXXXXXXXXX Ok e To set first private phone number as 05321234567 06 01 05321234567 Ok P S To erase any private number enter the same section on the program and pres...

Page 8: ... with Master Code Press and Hold the Key 4 Enter four digit Master Code Factory Default 1234 To set user code LED Keypad 07 01 1 User Code XXXX Ok LCD Keypad Basic Settings Ok User Codes Ok 01 User Code XXXX Ok e To set 1 User Code as 1111 07 1 1111 Ok To set 2 User Code as 2222 07 2 2222 Ok Important GSM GPRS CMS Communication and SMS configuration can be done only by Teknim PC Configuration soft...

Page 9: ...5 03 05 04 1 CMS PHONE NO 2 CMS PHONE NO 3 CMS PHONE NO 4 CMS PHONE NO Maximum 15 digit phone number 0 press long can give you space if you need time to wait for line To erase the phone number press and hold B Empty Empty Empty Empty InC MaC 06 PRIVATE PHONES 06 01 06 02 06 03 06 04 06 05 06 06 1 Phone Number 2 Phone Number 3 Phone Number 4 Phone Number 5 Phone Number 6 Phone Number Maximum 15 dig...

Page 10: ... Arm Days 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday 7 Sunday All Enable InC MaC 12 03 Auto Arm Time HH MM HH Hours MM Minutes 00 00 InC MaC 12 04 Auto Disarm Partitions 1 Partition A 2 Partition B 3 Partition C 4 Partition D Auto Disarm is disable if no partition is selected Disable InC MaC 12 05 Auto Disarm Days 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday 7 S...

Page 11: ...d Only TSP 5xxx InC 16 02 SW Version Read Only 0 InC 16 03 HW Version Read Only 0 InC 2 ZONE SETTINGS 20 CONNECTION TYPE 20 01 20 02 20 03 20 04 20 05 20 06 20 07 20 08 20 09 16 Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9 Z16 01 Keypad Zone 29 02 Keypad Zone 30 03 Keypad Zone 31 04 Keypad Zone 32 1 Opt NC NO 2 Opt Singl EOL Double Zone On Off 3 Opt Double EOL Double Zone On Off 4 Opt Zone Use In Use Not In Use 2 a...

Page 12: ... Z7 3 Z8 3 KZ1 3 KZ2 3 KZ3 3 KZ4 3 InC 24 RESPONSE TIME 24 01 24 02 24 03 24 04 24 05 24 06 24 07 24 08 Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 01 Keypad Zone 29 02 Keypad Zone 30 03 Keypad Zone 31 04 Keypad Zone 32 2 255 Calculated in multiples of 30 milliseconds Response Time Value x 30ms 15 450ms InC 25 ZONE NAMES ONLY WITH LCD KEYPAD Z1 Name Z2 Name Z3 Name Z4 Name Z5 Name Z6 Name Z7 Name Z8 Name Z9 Z16 Name ...

Page 13: ... Line 1 and 2 Company Information Only LCD Keypad All ON ALL ON ON ON ON ON ON ON ON ON ON ON Turkish InC MaC 4 USER SETTINGS 40 USER START TIME 40 01 40 02 40 03 40 04 40 05 40 06 40 07 40 08 40 09 40 10 1 User Start Time 2 User Start Time 3 User Start Time 4 User Start Time 5 User Start Time 6 User Start Time 7 User Start Time 8 User Start Time 9 User Start Time 10 User Start Time HH MM HH Hour ...

Page 14: ...t Yes No 3 Option One Time Code Yes No 4 Option One Day Code Yes No 5 Option Bypass Limitation Yes No 3 and 4 are valid only for the guest user 4 MaC 5 COMMUNICATOR 50 GENERAL OPTIONS 50 01 General Settings 1 Option CMS Call Yes No 2 Option User Call Yes No 3 Option SMS Yes No 4 Option Call Cancel When Disarm Yes No 5 Option Siren Warning When No Line Yes No 6 Option Confirmation from Phone Yes No...

Page 15: ...am Begin 21 Program End 22 Periodic Report 23 Panel Restart 24 Manuel Test 25 Disarmed by Phone 26 Disarmed by PC 27 Remote Connection 28 Module Fault 29 Reserved 30 Custom Event 31 24 Hour Alarm 32 Factory Default 1 Send Event to CMS 2 Send Event to Phone 3 Send Restore to CMS 4 Send Restore to Phone 5 Send Event to SMS 6 Send Restore to SMS Com Fault is only recorded in memory 33 64 are restores...

Page 16: ... QUICK INSTALLATION GUIDE MANUFACTURER Bilgi Elektronik Sanayi ve Ticaret A Ş Dudullu OSB 1 Cadde İsmet Tarman İş Merkezi No 1 Kat 2 No 32 Ümraniye İstanbul Phone 90 216 455 88 46 Fax 90 216 455 99 06 www teknim com sales bilgielektronik com tr ...