17 of 28
© 2011
D 530 - 12/11
Displa
y
Rang
e
A
ccess
Description
Set t
o
AD
JUST
A
D
JU
S
T
OFF
, 1 t
o
1
6
Installer
AIR GR
OUP
Select if t
his t
hermostat should be an air gr
oup mast
e
r.
Select of
f if t
he t
hermso
tat is no
t an air gr
oup mast
e
r.
Select 1 t
hough 1
6
t
o
select t
he air gr
oup number
.
A
vailable when:
The t
hermostat is connect
ed t
o
o
ther t
hermostats
using t
ekmarNe
t
®
.
•
0
1
t
o
2
4
(no r
ese
t contr
ol),
b:0
1 t
o
b:2
4
(r
ese
t contr
ol - boiler),
1:0
1 t
o
1:2
4
(r
ese
t contr
ol - mixing)
Installer
tekmarN
e
t
®
ADDRESS
The addr
ess is sho
wn in t
he large number field. “
A
ut
o” is
sho
wn in t
he upper number field when using aut
omatic
addr
essing.
Pr
ess t
he
or t
he
butt
on t
o
manuall
y select
an addr
ess.
The addr
ess can be r
e
turned t
o
aut
omatic “
A
ut
o”
addr
essing when addr
ess se
t abo
ve
2
4
.
FL
OOR
AD
JUST
A
D
JU
S
T
COOL
OFF or On
Def
ault = OFF
Installer
FL
OOR C
OOLING
Sele
ct
if the ther
most
at shou
ld
o
p
e
rate th
e h
e
at
in
g re
la
y
W for rad
ian
t f
lo
o
r c
o
o
lin
g
.
A
vaila
b
le when
:
Connect
ed t
o
a t
ekmarNe
t
®
heat pump or chiller sy
st
em
contr
ol AND heating t
erminal t
ype is se
t t
o
Hydr
onic
AND cooling t
erminal t
ype is se
t t
o
rEF or C
OIL.
•
None
Installer
User
ESC
APE
Pr
ess t
h
e
or t
he
butt
on t
o
r
e
turn t
o
normal
operation.
S
e
tt
ings (
8
of 8
)