For Tanks without pre-drilled holes
•
If the tank is not pre-drilled, then using a 30/32mm (1.22 inch)
hole saw, drill the hole in the top of the tank in a suitable area to
allow ease of fitting the sensor such that the sensor can see the
tank contents. Position it so that there are no internal
obstructions that may interfere with the ultrasonic signal (i.e. Ribs,
Stays, Side of Tank, internal equipment).
•
Use the
Appendix
diagram to ensure suitable fitting
.
•
Ensure the sensor is vertical on top of the tank.
•
Tighten on to the tank using the 2-stainless steel 19mm (0.75 inch)
long self-tapping screws supplied.
Do not use longer screws. Do
not over-tighten.
Check the Tekelek Eco Water Monitor display 2 hours after mounting the
sensor & verify that your Tekelek Eco Water Monitor
display shows the
tank level in the bar-graph area & the Water volume information in the
main display area. If not, please consult the ‘Troubleshooting’ section of
the Eco Water Monitor User Manual.
STEP 4: (OPTIONAL) PERFORM ONLY IF THERE WAS A DELAY IN
INSTALLING THE SENSOR ON THE TANK
You only need to complete this step if there was a gap of more than an
hour between completing STEP 2 and STEP 3.
When the sensor is installed and has been confirmed as working,
reset the
usage calculations
by pressing
SETUP
for 3 seconds to enter SETUP mode
and then press
ENTER
repeatedly until SETUP 10 is shown.
The segments at the bottom of the display will be flashing. Press the
ENTER
key for 5 seconds. The screen will temporarily show ‘CALC’ and
then returns to showing SETUP
1 - Setting the Time (hrs). Press
SETUP
to
leave SETUP mode.
Setup of your
Tekelek Eco Water Monitor
is now complete, and
it
will
now begin to monitor and track your Water consumption on a day to day
and week to week basis. On the ‘Days to Empty’ CURRENT information
screen, ‘---’ will be displayed for the first week in use.
APPENDIX:
Ensure that the sensor is vertical on top of the tank and that it is
positioned such that there are no internal obstructions that may interfere
with the ultrasonic signal.
Determine the shape of your tank by selecting your tank type that is
closest in shape to your tank from the pictures on the following chart. The
capacity on the tank should be noted.
•
Determine the dimensions of your tank either from manufacturer’s
data for the tank or by physically measuring the tank.
•
You only need to note the dimensions indicated on the following
chart.
•
For bunded tanks the information required is for the internal tank
only, where the sensor will be located.
•
To determine the tank height, measure from the top of the tank, i.e.
where the sensor will be positioned, to the bottom of the tank (N.B.
of the internal tank in a bunded tank)
•
Determine the capacity of the tank from the manufacturer’s data for
the brim-full and/or nominal capacity.
For further details on the Tekelek Eco Water Monitor, please refer to the
User Manual.
For more information on the Tekelek ECO Water Monitor please visit
our website www.tekelek.ie where a link to our YouTube page can also
be found.