background image

3.2. General safety instructions

WARNING

Dangers arising from improper use / unauthorised operations.

The operator must ensure that their authorised personnel are familiar with all the safety
indications in this manual in advance. The operator is responsible for ensuring that all work
is carried out by authorised and qualified personnel. We therefore recommend using the
training protocol on the last page for that purpose (see chapter “Training protocol”).
Laymen are allowed to operate the device after having received the necessary instructions.
But they are not allowed to carry out any installation, repair or maintenance work.
The operator must ensure that the device is not operated, opened, serviced or otherwise
confiscated by minors (persons younger than 18 years).

Dangers arising from fire.

In case of fire, if possible, switch the unit immediately off or disconnect it from the power
supply. Fire extinguishing measures which the operator is obliged to determine beforehand
must be initiated immediately.

WARNING

Dangers arising from electricity.

The operator must ensure that electrical plants and equipment are only built, modified and
maintained by a qualified electrician or under the direction and supervision of a qualified
electrician. Do not work on components if you are not sure that these are disconnected. If
necessary, disconnect the device from the electric power supply and secure it against
unauthorized restarting.

BA_VIROLINE-TOWER_201111_EN

6

12.01.2022

Summary of Contents for VIROLINE TOWER

Page 1: ...g instructions Translation of the original operating instructions VIROLINE TOWER TEKA Absaug und Entsorgungstechnologie GmbH Millenkamp 9 D 48653 Coesfeld Tel 49 2541 84841 0 E Mail info teka eu www t...

Page 2: ...perating the system 9 6 1 Explanation of the operating elements 9 7 Maintenance 10 7 1 Reset to maintenance state 11 7 2 Replacing the prefilter mat 11 7 3 Replacing the particle filter 12 7 4 Recplac...

Page 3: ...ir of the device The operator must ensure that the operating personnel take note of these instructions Please read these instructions before operating the device and observe the safety precautions to...

Page 4: ...4 Pos 5 Pos 6 Pos 7 Pos 8 Pos 9 Operating panel of the control Particle filter housing Fan housing Lamp housing Suction housing Air outlet housing Bumper Particle filter Prefilter mat Pos 10 Pos 11 Po...

Page 5: ...ed for the extraction of oil laden welding fume explosive dust and gases hybrid mixtures glowing or burning substances gases water etc The device must not be operated in explosive zones 3 Safety instr...

Page 6: ...ator must ensure that the device is not operated opened serviced or otherwise confiscated by minors persons younger than 18 years Dangers arising from fire In case of fire if possible switch the unit...

Page 7: ...ransport As a matter of principle the filter unit is not designed to be installed outside The unit is delivered in 2 parts upper part and lower part The lower part must first be transported to its des...

Page 8: ...efore switching it on The unit must not be operated without a filter element NOTICE Damaged supply lines Make sure that the supply lines are protected against damage by forklift trucks and similar eve...

Page 9: ...y from one another Our recommendation Switch the fan ON if there are persons in the room for long periods And only switch the UV C lamps ON if the fan is switched OFF Operating elements for status and...

Page 10: ...functionally equivalent to the original state CAUTION Hazards to the respiratory tracts are possible All maintenance work must only be carried out in well ventilated rooms and while wearing an approp...

Page 11: ...t be determined beforehand At the latest the prefilter mat must be changed when changing the particle filter CAUTION Whirling up dust is possible The prefilter mat is a disposable filter element Do no...

Page 12: ...f the particle filter housing see chapter 2 1 Lower the lifting device A by turning the clamping screw B Therefore use the hexagon key that is located on the right of the clamping screw Carefully pull...

Page 13: ...s elements Do not touch the glass elements with your fingers Use gloves Open the service door of the lamp housing see chapter 2 1 Now carefully pull all the UV C lamps A out from their sockets B To do...

Page 14: ...disconnected from the power supply and all supply lines CAUTION Whirling up dust is possible due to the deposited dust During all work a suitable respiratory protection and protective clothing have to...

Page 15: ...n carrying out any repairs If in doubt contact our TEKA service department Tel 49 2541 84841 0 E mail info teka eu Fault Cause Removal System does not start Plug power supply is missing or incorrectly...

Page 16: ...low volume max m h 3000 Protection class IP54 ISO class F Width Depth Height mm mm mm 785 800 3200 Weight kg 235 Sound pressure level dB A 65 Allowed ambient temperature C 5 to 35 during operations 10...

Page 17: ...above from the serial number A19400010011001 resp P44000010011001 on conforms to the following directives Machinery Directive 2006 42 EG Electromagnetic Compatibility 2014 30 EU This declaration will...

Page 18: ...ee confirms that he has been instructed regarding the following items Instruction completed Description of the device Operation and application of the device Explanation of the safety instructions Beh...

Page 19: ...terval The filter unit triggers an alarm when a replacement of the particle filter is necessary Replacing the prefilter mat or check the degree of pollution 7 2 quarter annually Replacing the UV C lam...

Page 20: ...itch on the device Pay attention to extraneous noises or vibrations during the device s operation Check if the collection of the ambient air is sufficient Visual inspection 14 2 3 Electrical test of t...