(*) If a failure in a sensor is displayed, follow the steps below:
- Check the wiring and conections between the sensor and de control board.
- Check the ohmic value of the sensor, and compare it with the table in section 8. If the
sensor is
“
open
”
(value
≈
∞
) or
“
short-circuited
”
(value
≈ 0Ω)
, it must be replaced.
- If the previous steps are correct, the control board must be replaced.
(**) In order to avoid fake alarms, error messages won
’
t be displayed under the
following conditions:
-
Within 6 hours after plugging the appliance to the power supply.
-
Within the defrost cycle.
-
Within 2 hours after a defrost cycle.
-
Within 2 hours after a door opening.