GB
10
2
Remove the cooker
’
s controls in order to
be able to access the gas taps.
3
Use a slim, grooved screwdriver to turn
the screw located to the left or in the
centre of the gas tap
’
s shaft (the flame
increases when you turn to the left and
decreases when you turn to the right).
4
When properly adjusted, check that the
flame does not go out when you turn the
knob quickly from maximum to mini-
mum.
TEKA INDUSTRIAL, S.A.
does not accept
liability for any hob malfunction if the gas
conversion or the adjustment of the bur-
ners
’
minimums has not been carried out
by TEKA
’
s official personnel.
Burner
Family
Second
Third
Group H
Group 3+
Triple crown
130
97
Rapid
116
85
Semi-rapid
97
66
Auxiliary
72
50
Ø
injector expressed in 1/100 mm.
Table 1