Teka E/70 2G AI TR Instructions For The Installation And Advice For The Maintenance Download Page 15

15

CONVERSIONS

BURNER ARRANGEMENT ON THE HOT PLATE

HONG KONG MARKET

LPG

30

269

95

1400

3700

62

TOWN

10

833

350 6

1400

4000

62

LPG 30

218

85

750

3000

45

TOWN

10

708

300 3

750

3400

45

LPG

30

127

65

500

1750

35

TOWN

10

365

190 2

500

1750

35

BURNERS

DESCRIPTION

GAS

NORMAL

PRESSURE

NORMAL

RATE

INJECTOR

DIAMETER

NOMINAL HEAT

INPUT (W)

mbar

g/h

l/h

1/100 mm

MIN.

MAX.

1/100 mm

LPG

30

73

50

400

1000

30

TOWN

10

208

145 2

400

1000

30

1

ULTRA RAPID

2

RAPID

3

SEMIRAPID 

4

AUXILIARY

BY

PASS

CHINA MARKET

LPG

30

269

85

1400

3700

62

NATURAL

20

352

130 T

1400

3700

62

TOWN (SHANGHAI)

10

971

330 3

1400

3700

62

TOWN (GUANGZHOU)

20

472

165 2

1400

3700

62

LPG

30

218

70

750

3000

45

NATURAL

20

286

91 Z

750

3000

45

TOWN (SHANGHAI)

10

787

260 3

750

3000

45

TOWN (GUANGZHOU)

20

383

140 1

750

3000

45

LPG

30

127

55

500

1750

35

NATURAL

20

167

80 Y

500

1750

35

TOWN (SHANGHAI)

10

459

200 2

500

1750

35

TOWN (GUANGZHOU)

20

223

110 1

500

1750

35

BURNERS

DESCRIPTION

GAS

NORMAL

PRESSURE

NORMAL

RATE

INJECTOR

DIAMETER

NOMINAL HEAT

INPUT (W)

mbar

g/h

l/h

1/100 mm

MIN.

MAX.

1/100 mm

LPG

30

73

50

400

1000

30

NATURAL

20

95

72 X

400

1000

30

TOWN (SHANGHAI)

10

262

135 11

400

1000

30

TOWN (GUANGZHOU)

20

128

87

400

1000

30

1

ULTRA RAPID

2

RAPID

3

SEMIRAPID 

4

AUXILIARY

BY

PASS

Summary of Contents for E/70 2G AI TR

Page 1: ...tallation and advice for the maintenance E 70 2G AI TR E 70 3G AI TR E 70 5G AI TR E 70 2G AI TR AL E 70 3G AI TR AL E 70 5G AI TR AL Instructions Manual E 70 2G AI TR E 70 3G AI TR E 70 5G AI TR E 70...

Page 2: ...ntral enamelled steel pan support for ur 8 Central enamelled steel pan support 9 Burner n 1 control knob 10 Burner n 2 control knob 11 Burner n 3 control knob 12 Burner n 4 control knob 13 Electric ig...

Page 3: ...ap is not correctly place In the event of the Burner flames being accidentally extinguished turn off the burner control and do not attempt to re ignite the burner for a least 1 minute HOW TO USE THE B...

Page 4: ...ents clear fig 3 and by activating the mechanical aeration device suction hood or electric fan fig 4 and fig 5 Intensive and lengthy use of the appliance may require additional ventilation This can be...

Page 5: ...the plate is operating A purely indicative regulation table for the normal electric plates is given below NORMAL AND RAPID PLATES HEAT INTENSITY POSSIBLE COOKING PROCESSES TABLE 0 1 2 3 4 5 6 Off Wea...

Page 6: ...he plates are being used Make sure that there are no children in the near vicinity Particularly make sure that the pan handles are correctly positioned and keep a check on foods requiring oil and gras...

Page 7: ...burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the hot plate Do not force the taps if they are d...

Page 8: ...ndicated in either fig 9 Always comply with the measurements given for the hole into which the appliance will be recessed see fig 9 and 10 The appliance belongs to class 3 and is therefore subject to...

Page 9: ...able to withstand a temperature of not less than 150 C otherwise the laminate could come unstuck The appliance must be installed in compliance with the provisions in force This appliance is not connec...

Page 10: ...e by means of the safety clamp specified by standards In case of liquid bottledgas supply mount a pressure governor according to the regulations in force To connect the hob with the bottled pressure g...

Page 11: ...ust be positioned so that no part of it is able to reach an overtemperature of 75 K Never use reductions adapters of shunts for connection since these could create false contacts and lead to dangerous...

Page 12: ...ing such appliances 11 FIXING THE HOT PLATE The hot plate has a special seal which prevents liquid from infiltrating into the cabinet Strictly comply with the following instructions in order to correc...

Page 13: ...which is simply pressed on to its rod Insert a small screwdriver D into hole C fig 15 and turn the throttle screw to the right or left until the burner flame has been adequately regulated to the Redu...

Page 14: ...thorized customer Service Centre For the sake of convenience the nominal rate table also lists the heat inputs of the burners the diameter of the injectors and the working pressures of the various typ...

Page 15: ...00 62 NATURAL 20 352 130 T 1400 3700 62 TOWN SHANGHAI 10 971 330 3 1400 3700 62 TOWN GUANGZHOU 20 472 165 2 1400 3700 62 LPG 30 218 70 750 3000 45 NATURAL 20 286 91 Z 750 3000 45 TOWN SHANGHAI 10 787...

Page 16: ...000 45 TOWN 10 581 270 3 750 3000 45 LPG 30 127 65 500 1750 35 TOWN 10 339 190 2 500 1750 35 BURNERS N DESCRIPTION GAS NORMAL PRESSURE NORMAL RATE INJECTOR DIAMETER NOMINAL HEAT INPUT W mbar g h l h 1...

Page 17: ...a tap is replaced to ensure a perfect tightness Greasing the taps see fig 21 22 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions Remove th...

Page 18: ...ur ambient Always put them in a separate and safe container If you eliminate your appliance remember to take off the battery FIG 23 CAUTION The device should not be operated for more than 15 second If...

Page 19: ...PE OF SINGLE PHASE HOT PLATE CABLE POWER SUPPLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installe should leave the ground wire longer than the phase conductors fig...

Page 20: ...30 mbar PROPANE 37 mbar NATURAL 20 mbar Tot Nom Gas Rate 7 4 kW Tot Nom LPG Rate 538 g h Voltage 220 230 V Frequency 50 Hz OTHER MARKETS 5 BURNERS BUTANE 28 30 mbar PROPANE 37 mbar NATURAL 20 mbar Tot...

Page 21: ...LPG 30 mbar TOWN 10 mbar Tot Nom LPG Gas Rate 7 4 kW Tot Nom H K TowngasRate 8kW Tot Nom LPG Rate 538 g h Voltage 220 230 V Frequency 50 Hz 5 BURNERS LPG 30 mbar TOWN 10 mbar Tot Nom LPGGasRate 11 2k...

Page 22: ...L 20 mbar TOWN SHANGHAI 10 mbar TOWN GUANGZHOU 20mbar Tot Nom Gas Rate 7 4 kW Tot Nom LPG Rate 538 g h Voltage 220 230 V Frequency 50 Hz 5 BURNERS LPG 30 mbar NATURAL 20 mbar TOWN SHANGHAI 10 mbar TOW...

Page 23: ...ency 60 Hz 2 UR BURNERS LPG 30 mbar NATURAL 20 mbar Tot Nom Gas Rate 7 4 kW Tot Nom LPG Rate 538 g h Voltage 110 V Frequency 60 Hz 5 BURNERS LPG 30 mbar NATURAL 20 mbar Tot Nom Gas Rate 11 2 kW Tot No...

Page 24: ...RNERS LPG 30 mbar TOWN 10 mbar Tot Nom LPGGasRate 6 7kW Tot Nom TowngasRate 6 2kW Tot Nom LPG Rate 488 g h Voltage 220 230 V Frequency 50 Hz 5 BURNERS LPG 30 mbar TOWN 10 mbar Tot Nom LPGGasRate 10 85...

Page 25: ...50 60 Hz 2 UR BURNERS LPG 28 30 mbar NATURAL 20 mbar Tot Nom Gas Rate 7 4 kW Tot Nom LPG Rate 538 g h Voltage 220 V Frequency 50 60 Hz 5 BURNERS LPG 28 30 mbar NATURAL 20 mbar Tot Nom Gas Rate 11 2 k...

Page 26: ...Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spare parts are only ava...

Page 27: ...01 600 3 762 01 626 MALAYSIA Mexico Mexico D F TEKA MEXICANA S A DE C V 52 5 762 04 90 5 762 05 17 Poland Warszawa TEKA POLSKA SP Z O O 48 22 652 18 94 22 850 12 48 Portugal Ilhavo TEKA PORTUGUESA LT...

Page 28: ...28...

Reviews: