General description. 

 

This  document  contains  the  technical  information  for  the  related  models  (wiring 
diagrams, main components features, etc.), meaning of error messages, how they are 
shown and how to perform a service test and their phases.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for DW 605 S VR01

Page 1: ...400 LPM 819 DW8 40 FI LP8 410 LPZ 417 DW8 41 FI LP8 700 LPZ 817 BL INOX DW8 55 FI LP8 810 LVS 831 BL INOX DW8 57 FI LP8 818 DW 605 S VR01 VR02 DW8 58 FI LP8 820 DW 455 S VR01 DW8 70 FI LP 825 DW1 605 FI VR01 VR02 DW9 70 FI LP8 840 VR01 VR02 DWM 859 FI LP8 440 VR01 VR02 DWZ 57 FI LP9 850 LP9 840 LP9 440 ...

Page 2: ...00 LP8 400 9 8 LP8 810 LP8 818 LP8 410 LPM 819 LPZ 417 LVS 831 LPZ 817 10 9 LP8 820 LP8 825 11 10 LP8 840 VR01 VR02 LP8 440 VR01 VR02 12 11 LP8 850 VR02 VR03 13 12 LP2 140 14 13 DW8 55 FI DW8 40 FI DWM 859 FI DWZ 57 FI 15 14 DW8 57 FI DW8 58 FI DW8 41 FI 16 15 DW8 70 FI 17 16 DW1 605 FI DW1 455 FI VR01 VR02 19 17 DW 605 S VR01 VR02 DW 455 S VR01 20 18 LP9 850 LP9 840 LP9 440 21 ...

Page 3: ...12 2 1 General description This document contains the technical information for the related models wiring diagrams main components features etc meaning of error messages how they are shown and how to perform a service test and their phases ...

Page 4: ...Service Manual Service Manual MSDW16012 3 2 Hydraulic diagram The inlet valve can be assembled in the inlet pipe depending on the model ...

Page 5: ...generación PK Pink rosa EV3 Opc 1 Water diverter válvula lavado alternado PU Purple morado FM Flowmeter caudalímetro RD Red rojo IAQS Overflow switch interruptor desbordamiento WH White blanco ISB Rinse aid detector detector abrillantador YE Yellow amarillo ISS Salt detector detector sal ML Wash pump bomba de lavado P1 Safety level Pressure switch presostato seguridad P2 Heater pressure switch pre...

Page 6: ...del is equipped with turbidity sensor the display will show the value it is measuring 2 04 temp 8 0 The washing pump starts working at high speed and 10 seconds later the heater element will turn on until water temperature reaches 57º C Then the test will pause until the Program or Start Pause depending on the model button is pressed 3 03 0 4 0 05 The washing pump starts working at low speed After...

Page 7: ...k Turn on the water tap Low water pressure 0 04MPa User to check Turn on the water tap and ensure full opening position Pressure switch is broken stop at inlet process Replace the pressure switch Inlet valve is broken no water in tub Replace the Inlet valve Drain pump is broken water cannot drain out Replace the drain pump Wire terminal which connects the pressure switch is loosen Reconnect the wi...

Page 8: ...oken or PCB is faulty Replace the float switch or the PCB E6 Wire terminal connected to the temperature sensor is loosening Wire terminal connected to the temperature sensor is short circuited or open circuited Reconnect the wire terminal or replace the sensor E7 E8 Wiring damage or alternate valve failure Check connections or replace valve E9 Sensor button pressed for more than 30 s Check if ther...

Page 9: ... If the flowmeter is ok the multimeter should beep intermittently Washing pump Power supply 220 240 V Main coil resistance 116 4 Ω 7 Secondary coil resistance 101 5 Ω 7 Capacitor 3μF Draining pump Power supply 220 240 V Coil resistance 235 Ω 15 Ω Heating element Power supply 230 V Rated power 1800 W Resistance 29 3 Ω 1 47 Ω Alternate valve Opc 1 Power supply 230 V Resistance 5 75 K Ω Turbidity sen...

Page 10: ...3 Optional Components None Hydraulic diagram See section 2 Error indication Service Test Follow the next steps to launch the test service Connect the appliance to the power supply Keep pressed the Start Pause button 5 The door must be open Press and release ON OFF button 1 All leds from control panel start to blink Once the door is closed service test will start You can advance to the next step of...

Page 11: ...cet indicator 7 ON OFF indicator Wiring diagram See section 3 Optional Components None Hydraulic diagram See section 2 Error indication Service Test Follow the next steps to launch the test service Connect the appliance to the power supply Keep pressed the Start Pause button 6 The door must be open Press and release ON OFF button 1 All leds from control panel start to blink Once the door is closed...

Page 12: ...ring diagram See section 3 Optional Components None Hydraulic diagram See section 2 Error indication Display Service Test Follow the next steps to launch the test service Connect the appliance to the power supply Keep pressed the Start Pause button 12 The door must be open Press and release ON OFF button 1 All leds from control panel start to blink Once the door is closed service test will start Y...

Page 13: ...nlet hose Hydraulic diagram See section 2 Error indication Display Service Test Follow the next steps to launch the test service Connect the appliance to the power supply Keep pressed the Program button 4 The door must be open Press and release ON OFF button 1 All leds from control panel start to blink Once the door is closed service test will start You can advance to the next step of the test by ...

Page 14: ...sh valve Opc 1 Hydraulic diagram See section 2 Error indication Display Service Test Follow the next steps to launch the test service Connect the appliance to the power supply Keep pressed the Program button 4 The door must be open Press and release ON OFF button 1 All leds from control panel start to blink Once the door is closed service test will start You can advance to the next step of the tes...

Page 15: ...raulic diagram See section 2 Error indication Display Service Test Follow the next steps to launch the test service Connect the appliance to the power supply Keep pressed the Start Pause button 8 The door must be open Press and release ON OFF button 1 All leds from control panel start to blink Once the door is closed service test will start You can advance to the next step of the test by pressing ...

Page 16: ...l Components Aquastop inlet hose Hydraulic diagram See section 2 Error indication Service Test Follow the next steps to launch the test service Connect the appliance to the power supply Keep pressed the Program button 2 The door must be open Press and release ON OFF button 7 All leds from control panel start to blink Once the door is closed service test will start You can advance to the next step ...

Page 17: ...Wiring diagram See section 3 Optional Components Aquastop inlet hose Hydraulic diagram See section 2 Error indication Display Service Test Follow the next steps to launch the test service Connect the appliance to the power supply Keep pressed the Program button 12 The door must be open Press and release ON OFF button 13 All leds from control panel start to blink Once the door is closed service tes...

Page 18: ...sensor Opc 2 Hydraulic diagram See section 2 Error indication Display Service Test Follow the next steps to launch the test service Connect the appliance to the power supply Keep pressed the Program button 4 The door must be open Press and release ON OFF button 1 All leds from control panel start to blink Once the door is closed service test will start You can advance to the next step of the test ...

Page 19: ...pc 1 turbidity sensor Opc 2 Hydraulic diagram See section 2 Error indication Display Service Test Follow the next steps to launch the test service Connect the appliance to the power supply Keep pressed the Program button 2 The door must be open Press and release ON OFF button 1 All leds from control panel start to blink Once the door is closed service test will start You can advance to the next st...

Page 20: ...ptional Components Aquastop inlet hose Hydraulic diagram See section 2 Error indication Service Test Follow the next steps to launch the test service Connect the appliance to the power supply Keep pressed the Program button 8 The door must be open Press and release ON OFF button 9 All leds from control panel start to blink Once the door is closed service test will start You can advance to the next...

Page 21: ... 3 Optional Components Aquastop inlet hose Hydraulic diagram See section 2 Error indication Service Test Follow the next steps to launch the test service Connect the appliance to the power supply Keep pressed the Start Pause button 5 The door must be open Press and release ON OFF button 1 All leds from control panel start to blink Once the door is closed service test will start You can advance to ...

Page 22: ...m See section 3 Optional Components Aquastop inlet hose Alternate wash valve Turbidity sensor only LP9 850 Dry fan only LP9 850 Hydraulic diagram See section 2 Error indication Display Service Test Follow the next steps to launch the test service Connect the appliance to the power supply Keep pressed the Start Pause button 11 The door must be open Press and release ON OFF button 1 All leds from co...