Page 1: ...as Extractoras DR 90 Bedienungsanleitung Dunstabzugshauben DR 90 Instructions Manual Kitchen Hoods DR 90 Manuel d instructions Hottes aspirantes DR 90 Manual de Instruções Exaustores DR 90 Manual DR TEKA qxd 12 01 2005 16 53 Page 1 ...

Page 2: ...t have sufficient ventilation Excessive fat accumulation in the kitchen hood and metal filters is a fire risk and may also cause dripping therefore the inside of the kitchen hood and the metal filters must be cleaned at least once a month The lower part of the kitchen hood must be fitted at least 50 cm over electric hobs and 65 cm over gas or mixed hobs FOLLOW THE MANUFACTURER S MINIMUM RECOMMENDA...

Page 3: ... fan to run for several minutes after you have finished cooking between 3 to 5 minutes in order to expel all the grease from the outlet duct This prevents the return of grease smoke and smells 1 The draft hood will remain on for 10 minutes at the selected level if pressed at any speed for more than 2 seconds To programme a time other than the pre selected one 10 minutes a Press the Timer button wi...

Page 4: ...rface blackening it although this will not affect its fat retention capacity Once clean leave them to dry off and then fit them onto the kitchen hood Proceed as follows Unscrew the lamp cap trimming cover Change the broken burnt out lamp Maximum lamp power is 20 W G 4 Screw in the lamp cap trimming cover Cleaning and maintenance _________________________________________________________ Problem sol...

Page 5: ...Technical Code Network Tension V Network Frequency Hz Lights Motor Power W Motor Volume 114321DR 220 240 50 2 x 20 250 800 m 3 h 134321DR 110 127 60 2 x 20 280 730 m 3 h TEKA INDUSTRIAL S A reserves the right to make changes and corrections to its products as it deems necessary without altering their basic characteristics Manual DR TEKA qxd 12 01 2005 16 53 Page 17 ...

Page 6: ...Centre the support C around the shape marked trace and drill the fixing points for the wall plugs E Ø6 x 30 Attach the support C with the long bolts D Ø4 x 30 11 Fit the part A if the inner tube not supplied is Ø150 or A B if it is Ø120 12 Attach the inner tube with a clamp not supplied to A or B as the case may be 13 Once the inner tube has been fitted fit the lower tubecover around the extractor...