background image

POWER PIPE™ SYSTEM

Power Pipe™ Stake

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF TEKA ILLUMINATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY 

DESCRIBE.  REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF TEKA ILLUMINATION IS STRICTLY FORBIDDEN.

RELEASE DATE

9-12-17

DRAWING

 

NUMBER

INS-001082

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF TEKA ILLUMINATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY 

DESCRIBE.  REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF TEKA ILLUMINATION IS STRICTLY FORBIDDEN.

Warning

High Voltage

NEEDED

FOR 

INSTALLATION:

By Others

Hot Surface

Optional  

Stability  

Flange

Specify Fixture 

Separately

12V In

12V Out

120V In

12V Out

120V In

12V or

120V Out

12V or

120V Out

Conduit

or UF Cable

Conduit

or UF Cable

Conduit

or UF Cable

GRADE

GRADE

Power Pipe™ 

Junction Box 

with ‘B’ Cap

Power Pipe™ 

Junction Box 

with integral 75VA 

transformer for 

remote fixtures 

with ‘C’ Cap

Power Pipe™ 

Junction Box 

with integral 75VA 

transformer

with ‘B’ Cap

with integral 75VA 

transformer for 

remote fixtures 

with ‘C’ Cap

with integral 75VA 

transformer

with ‘B’ Cap

12V In

12V Out

Power Pipe™ 

Stake 

with ‘B’ Cap

GRADE

12V Out

Power Pipe™ 

Stake 

GRADE

120V In

120V In

Power Pipe™ 

Stake 

GRADE

12" or

18"

2" Dia. PVC

Housing

Two 1/2" 

PVC Slip 

Connectors

PP Stake ‘S’

PP Junction ‘J’

12" or

18"

2" Dia. PVC

Housing

Specify Fixture 

Separately

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS

IMPORTANT - WEAR GLOVES TO AVOID GETTING FINGERPRINTS ON THIS PRODUCT. MANY TEKA ILLUMINATION PRODUCTS ARE DESIGNED TO NATURALLY PATINA. 

OILS FROM YOUR SKIN WILL ACCELERATE THIS PROCESS WHERE TOUCHED AND ARE NEARLY IMPOSSIBLE TO REMOVE. THIS PROCESS OCCURS OVER TIME AND IS 

DETERMINED BY THE INSTALLATION ENVIRONMENT.

·  Suitable for wet locations

IMPORTANT LISTINGS AND CERTIFICATIONS

Please refer to the low voltage design guide at www.tekaillumination.com/lvguide before installation for proper wire selection. 

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS

• Product must be installed by a qualified person in a manner 

consistent with its intended use and in compliance with the 

National Electrical Code, Canadian Electrical Code, and all Local and 

Provincial Codes. 

•  Follow product label information and instructions.

• Qualified Personnel with appropriate personal protective 

equipment must perform all servicing of this product.

•  Before wiring to power supply and during servicing, turn off and 

lock out power at fuse or circuit breaker before service.

• The use of accessory equipment not recommended by the 

manufacturer or installed contrary to instructions may cause an 

unsafe condition. The use of damaged components may cause an 

unsafe condition and void product warranty.

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY 

AND INSTALLATION INSTRUCTIONS

•  Do not block light emanating from product in whole or part, as 

this may cause an unsafe condition.

• Never operate the fixture with missing or damaged lens.  

Lens must be cleaned on regular basis.

• Entire fixture may become extremely hot. Do not touch hot 

lens or fixture body. 

•  Replace LED assembly only with correct wattage and type of 

power supply appropriate for LED assembly.

• All gaskets, o-rings and sealing surfaces must be kept clean 

during installation and service; failure to do this may cause an 

unsafe condition and void product warranty. 

INSTRUCTIONS PERTAINING TO 

A RISK OF FIRE, OR INJURY TO 

PERSONS IMPORTANT SAFETY 

INSTRUCTIONS

Lighted fixture is HOT!

WARNING - To reduce the risk of 

FIRE OR INJURY TO PERSONS: 

Turn off/unplug and allow to cool before replacing LED. 

Fixture gets HOT quickly! Contact only switch/plug when 

turning on.  Do not touch hot lens, guard, or enclosure. 

Keep fixture away from materials that may burn. 

 

Do not operate the luminaire fitting with a missing or 

damaged shield.  Do not touch the source at any time. Use 
a soft cloth or gloves. Oil from skin may cause damage.

SAVE THESE INSTRUCTIONS

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.tekaillumination.com • [email protected]

5/64” Allen Wrench
Waterproof Wire Connectors

Phillips Screwdriver

Summary of Contents for PP 204

Page 1: ...nstalled by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing t...

Page 2: ...ER INS 001082 2 Route the necessary UL approved under ground branch circuit or low voltage wiring to Power Pipe necessary for appropriate installation Leave enough length to make connections to lamp leads 3 Back fill hole with soil and or prep for concrete 4 Pull branch circuit or low voltage wiring necessary for appropiate installation By Others 1 Excavate trench according to designed lighting pl...

Page 3: ...KA ILLUMINATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE DISCLOSE ITS CONTENTS OR TO MANUFACTURE USE OR SELL ANYTHING IT MAY DESCRIBE REPRODUCTION DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF TEKA ILLUMINATION IS STRICTLY FORBIDDEN DRAWING NUMBER INS 001082 1 Pull primary branch circuit through transformer T housing Attach ground from branch circuit to s...

Page 4: ...T Suitable for wet locations IMPORTANT LISTINGS AND CERTIFICATIONS Please refer to the low voltage design guide at www tekaillumination com lvguide before installation for proper wire selection IMPORTANT SAFETY INFORMATION READ FOLLOW AND SAVE THESE INSTALLATION INSTRUCTIONS Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the Nati...

Page 5: ...RAWING NUMBER INS 001082 1 Make watertight connections from remote magnetic transformer to fixture leads using waterproof wire connectors By Others JUNCTION BOX WITH B CAP 2 Attach ground from branch circuit to screw in transformer T housing Place transformer and connectors into T housing 3 Attach C cap and transformer T housing to Power Pipe with 3 8 32 round head Phillips stainless steel screws ...

Page 6: ...en wrench 3 Make watertight connection from primary branch circuit to primary side of transformer using waterproof wire connectors By Others Attach secondary leads from transformer to fixture leads using waterproof wire connectors By Others See wiring diagram JUNCTION BOX WITH INTEGRAL TRANSFORMER AND B CAP 1 Pull primary branch circuit through transformer T housing Attach ground from branch circu...

Reviews: