![TEKA ILLUMINATION LARGE BEACON WALL MOUNT Quick Manual Download Page 2](http://html1.mh-extra.com/html/teka-illumination/large-beacon-wall-mount/large-beacon-wall-mount_quick-manual_1076201002.webp)
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
DATE
5-3-18
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.tekaillumination.com • [email protected]
REFERENCE NUMBER
INS-2691-00
19”
5”
17”
3”
Junction Box
2. Drill mounting holes in surface around junction
box as per lighting plan. Mounting holes are
17” apart on center vertically and 3” apart
horizontally on center. Canopy should be
oriented so that fixture stem is centered over
junction box.
Phase 2 - Fixture Installation
WIRING DIAGRAM
3. Connect remote driver secondary wiring to
fixture leads using watertight wire connectors (By
Others) as per NEC. Place wiring and connections
into junction box.
See wiring diagram.
4. Mount plate with mounting hardware (By
Others) over junction box. Use mounting
hardware (By Others) appropriate for surface.
Seal building envelope as per NEC. Do not
overtighten.
LARGE BEACON WALL MOUNT™ (LBW)
Phase 1 - Rough In
Installation of Back box
1. Install Conduit (By Others) to be used with
this product.
2. Install junction box (By Others) so that
front face is flush with finished wall. Seal to
building envelope as per NEC.
3. Connect box to conduit and pull wires for
connections (See wiring diagram).
Additional Info
• Please follow National and Local electrical codes for your area.
• Suitable for through wire.
• Suitable for installation into combustible materials.
• Rated for 90° C.
• Junction box, universal mounting ring screws, box mounting hardware
and gaskets (By Others)
Junction box must be secured to a structural member suitable for
weight of the luminaire and other weight likely to be placed upon it.
LINE
Red
FIXTURE
COM
Hydrolock
Plate
Black
GROUND
Driver
White
Black
Green
DIM +
DIM -
Black
White
Hydrolock
Plate
Green
Driver
White
Black
White
Blue
Green
LINE
COM
GROUND
Orange
Orange
Brown
Blue
Black
Gray
FIXTURE
FIXTURE
Green
Green
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
HP2RM
HP2 TR
TMB
PCIII
Generic TR
GROUND IN HOUSING
LINE
Quick
Connect
COM
Driver
FIXTURE
DIM +
DIM -
PM3
GROUND IN HOUSING
LINE
Quick
Connect
COM
Driver
FIXTURE
DIM +
DIM -
Quick
Connect
Driver
FIXTURE
DIM +
DIM -
PM3D
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
Fixture
Fixture
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
LINE
Red
FIXTURE
COM
Remote
Driver
Black
DIM +
DIM -
MA/AP
GROUND
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
DIM +
DIM -
PM3DRM
Fixture
Fixture
Remote
Driver
Fixture
Fixture
5. Connect secondary leads in stem with secondary
leads from fixture body with quick disconnect.
1. Remove fixture body from stem by loosening
two (2) #8-32 set screws with a 5/64” Allen
wrench. Disconnect quick disconnect from leads
to fixture body.
6. Slide fixture body onto stem, then secure by
tightening two (2) #8-32 set screws with 5/64”
Allen wrench.