7.6. Electrical installation
Installation must be carried out by qualified
personnel according to EN 10683. Ensure that the
electrical installation is earthed.
With the switch off, connect the cable to the
wall socket and plug.
Figure 7
Turn on the switch to electrically power the stove.
Figure 8
For more information, see point 10- Error codes
It occurs if the hopper (85ºc)
or
Circulator pump blocked with
dirt, installation with air in the
circuit, or closed radiator
valves.
Er02 Combustion chamber safety
Occurs if the combustion fan
cannot make a depression in
the
Door or ash drawer not
properly closed.
Silicone tube or clogged
pressure socket.
Return of wind through the
chimney
Extinguishing combustion due
to low smoke temperature,
lack of fuel
temperature drops below the
minimum
Too-down correction of pellet
recipe
Er04 Boiler temperature sensor
Circulator pump blocked, air in
circuit or any valve closed or
blocked.
Extinguishing combustion due
to
Lack of cleaning of the smoke
circuit.
Lack of dissipation, obstructed
or blocked ambient fan.
Correction too upwards of the
pellet recipe
Occurs if the rotation signal is
not received by the controller.
Check the plug and connecting
cable on the fan and controller
Occurs if the controller is
unable to obtain rotational
speeds according to the value
defined by it.
Check the plug and connecting
cable on the fan and controller
Possible fan or encoder
malfunction
Occurs if the boiler water
pressure drops below 0.4bar
Water pressure dropped below
0.4bar.
Occurs if the water pressure
exceeds the value of 2.4 bar
Check the auto-fill valve, it
may be blocked.
When the water reaches 75ºc,
the pressure must not rise by
more than 0.5 bar.