tefen MixRite 2.5 User Manual Download Page 15

 

  

 

 

6. 

MAINTENANCE 

 
Important! 

-  To maintain the dosing pump  in  good  condition, it  is  advisable  to  operate the 

pump with suction of clean water after each use. 

-  Regular yearly maintenance will help extend the lifespan of your MixRite dosing 

pump. In addition, kit seals need to be replaced every year. 

-  Regularly clean the water filter at the pump inlet and the fertilizer suction filter. 
-  If the pump  is planned to  be out of use for a long period  of time, operate the 

pump  for  a  few  minutes  with  the  suction  tube  immersed  in  a  tank  with  clean 
water to remove fertilizer residues from the pump, preventing them solidifying in 
the pump. 

-  If there is a fear of frost, and the temperature falling below 4°C (39ºF), empty 

the water from the pump. To do this, close the entry and exit valves securely. 
Open  and  dismantle  record  nut  that  connects  the  suction  pipe.  Press  the 
backflow prevention valve using a finger or a thin rod, allowing all the water that 
has collected in the pump to drain out while pressing the air-release valve at the 
top of the pump. 

-  It is advisable to carry out the maintenance of the pump body whenever soluble 

products are used. To carry out the maintenance, remove the pump body and 
wash  it  thoroughly  with  plenty  of  clean  water.  When  finished  and  before 
reassembly onto the motor body, lubricate the seal with silicone. 

 

ACTION 

FREQUENCY 

Cleaning cycle 

After each use 

General check  

Yearly 

Replace seals 

Yearly  

Replace other components 

As needed 

 
 
 

 

 

Summary of Contents for MixRite 2.5

Page 1: ...Propotional Pump Nahsholim 30815 Israel Tel 972 4 6395554 Fax 972 4 639 0813 www tefentech com E mail info tefentech com User Manual...

Page 2: ...cy and easy operation We wish you an excellent user experience with our product Please read this manual carefully before using the product and follow the safety guidelines For support please contact o...

Page 3: ...e additive injection directly into the water or fluid line with various flow rates feed ratios and pressure ranges These pumps are extremely durable manufactured from engineered composite materials to...

Page 4: ...9 4 2 MixRite Installation 10 4 2 1 Installing the MixRite on a Direct Line in line 11 4 2 2 Installing the MixRite on a Bypass Line offline 12 5 Operation 13 5 1 Adjusting the MixRite 13 5 2 Air Rel...

Page 5: ...ended to periodically check that the solution is being correctly drawn up into the MixRite Be extremely careful in the presence of hazardous substances e g corrosives toxins solvents acids caustic fla...

Page 6: ...L Height Air Release On Off Max 496 19 5 528 20 7 Min 457 17 9 497 19 5 160 6 3 L A A A A L 160 6 3 219 8 62 260 102...

Page 7: ...3 CONFIGURATION 01 0 1 0 9 04 0 4 4 05 0 5 5 22 0 2 Fix 28 0 8 Fix...

Page 8: ...ositioned above the liquid additive container Do not install the MixRite above an acid container fumes may damage the MixRite and protect it from possible contact with corrosive products The MixRite m...

Page 9: ...4 1 2 Mounting on Stand Stand delivered upon request...

Page 10: ...g pump in installations in which there is a risk of siphoning The strainer must be suspended at least 10 cm 4 above the bottom of the additive tank to avoid sucking up the insoluble particles that may...

Page 11: ...4 2 1 Installing the MixRite on a Direct Line in line...

Page 12: ...4 2 2 Installing the MixRite on a Bypass Line offline...

Page 13: ...obtain the desired result Adjustment must be made when there is no pressure in the MixRite Turn off the water supply and allow the pressure to drop to zero Do not remove the lower U Latch For maintena...

Page 14: ...t On pumps with On Off knob there is no air release valve It is highly recommended to use the On Off knob when the additive container is empty or if there is a need for the water flow to continue with...

Page 15: ...If there is a fear of frost and the temperature falling below 4 C 39 F empty the water from the pump To do this close the entry and exit valves securely Open and dismantle record nut that connects the...

Page 16: ...2 Wash the external surface of the unit with clean water 6 2 Cleaning and Refitting the Suction Check Valve Before removing Suction Check Valve turn off the water supply and allow the pressure to drop...

Page 17: ...tion pump test at low pressure Disconnect the water outlet hose from the outlet by installing a bypass make sure there is no water returning to the pump If the pump is working check the P as described...

Page 18: ...rn valve MixRite makes scratching noises Check if there is liquid in the additive container Add liquid to the container Check if the suction pipe is immersed and not folded Straighten or change the pi...

Page 19: ...8 SPECIFICATIONS 7...

Page 20: ...e and or defective installation or environmental accidents or corrosion by foreign bodies and liquids found within or in proximity to the MixRite The seals and O rings are not covered under warranty n...

Reviews: