InjectRite
Proportional Peristaltic Pump
User Guide
79
0
00
03
5
07
.2
22
Page 1: ...InjectRite Proportional Peristaltic Pump User Guide 79000000035 07 2022...
Page 2: ...1 256 200 128 100 64 50 Power Plug 220V 110V Water Meter Input 1 pulse per 1 liter 1 pulse per 0 1 or 1gallon gallon Tube Material Santoprene Pump Tube Connection 3 8 BSPT 3 8 NPT Max Injection 12 L H...
Page 3: ...ulator and that the line s counter pressure does not exceed 2 5 bar 36 psi 2 4 Insert the suction tube into the additive tank Make sure the tube is fully immersed inside the liquid but floats above th...
Page 4: ...7 Open the line s water flow and press constantly on Prime until the suction tube is filled with additive 2 8 Now the pump is operating automatically according to the water flow rate When the mainline...
Page 5: ...r 2 is displayed Flow rate exceeds the maximum allowed The pump will operate in full capacity with inaccurate dosage rate Reduce the water flow rate below the threshold Or reduce the dosage rate and k...
Page 6: ...stem WM1 CM1 Connectors for dry pulse signals from the water meter into the pump WM1 black CM1 white RR1 RR2 connectors for dry pulse signals from the pump into the controller or to the second pump to...
Page 7: ...Page 7 Kibbutz Nahsholim 3081500 Israel Tel 972 4 6395554 Fax 972 4 6390813 info tefentech com www tefentech com Single Installation Parallel Installation InjectRite InjectRite InjectRite...
Page 8: ...om www tefentech com Maintenance Period Maintenance Action 1 Week Cleaning the suction filter 2 1 month Add grease on the suction tube 3 6 months Tight the connectors 4 The rollers working properly 5...
Page 9: ...Page 9 Kibbutz Nahsholim 3081500 Israel Tel 972 4 6395554 Fax 972 4 6390813 info tefentech com www tefentech com 2 Remove the old squeeze tube and insert a new tube 3 Close the head cover...
Page 10: ...ch com www tefentech com Spare Parts Description SKU Photo No Squeeze Tube Kit 36600000003 1 Pump mounting plate 81 63 38000000311 2 Rinse Pump head kit 81 118 16 38000000312 3 Motor Gearbox 380000003...
Page 11: ...any products that have a normal life shorter than one year or failure and damage caused by chemicals corrosion physical abuse or misapplication Rubber and synthetic rubber parts such as o rings diaphr...