Operation Instruction for Display Cabinet
7
Setting of the digital controller
1
Refer to the digital controller operating manual to see how to use the
controller.
2
The setting values for the products as follows:
LABLE
DESCRIPTION
VALUES
LDP- series
LCT
series
SET
Set Point
2℃
2℃
Hy
Differential
3℃
3℃
od
Output activation delay at start up
1min
1min
AC
Anti-short cycle delay
5min
4min
CH
kind of action
cL
cL
rE
Resolution(only for ℃)
in
in
id
Interval between def. cycles
6h
3h
Md
Max length for def.
15min
15min