technicaL specifications
TD 210
Power consumption
kW
0.24
Power supply
V / Hz / Ph
230 / 50 / 1
Current (nom.)
A
1.4
Dehumidifying capacity (moisture
removal at 32ºC, 80%RH)
L / 24h
10
Dehumidifying capacity (moisture
removal at 27ºC, 60%RH)
L / 24h
5.7
Capacity water container
L
1.7
Air flow (nom.) *
m
3
/h
120
For rooms up to *
m
3
40 - 60
Operating range
°C
5 - 35
reciprocating
Refrigerant type / charge
r / gr
R134a / 90
Pressure suction / discharge
bar
12 / 24 (max. 25)
Dimensions (w x d x h)
mm
350 x 275 x 452
Net weight
kg
11
Gross weight
kg
12
Sound pressure level
dB(A)
45
Unit protection
IP
X0
3.15A/250V
Fuse rating
Model
Compressor type
* To be used as indication
Subject to change without prior notice.
perforMaNce GrapH
100
75
50
25
0
3
6
9 12 15 18 21 24 27 30 33
T [°C]
[L/24h]
80 % RH
60 % RH
50 % RH
(to be used as indication only)
4
59
man_TD210 ('11).indd 59