15. Reposition 4 wing nuts on the mounting stud, but do
not tighthen them.
16. Raise the wick to its highest position and tighten the
wing nuts in several steps.
17. Check the wick height. It should be 5/16 inch above the
collar.
18. Check for the correct clearance between wick holder
and draft tube. It should be the same all around.
19. Reinstall the tip-over switch assembly by pushing the
extinguish knob
.
20. Check the function of the tip-over safety stop by push-
ing the extinguish button
to activate the pendulum.
21. Reinstall the automatic ignition assembly.
22. Reinstall the wind cover A / B.
23. Reinstall the lamp cover
K
.
24. Reinstall the cabinet
.
25. Tighten the 5 screws on the cabinet and reinstall the
sensor at the back of the cabinet
.
26. Reinstall the combustion chamber
4
and the fuel tank
.
27. Reinstall the wick adjusting knob
2
and ignition
button
3
. Close the front plate.
Install the batteries in the battery case and fill the fuel tank
with Premium Quality Fuels. Put the tank into the heater
and wait at least 180 minutes for the new wick to fully satu-
rate with the fuel.
STEP 16
16
15
STEP 18
18
26
27
24
STEP 23
23
STEP 22
22
STEP 17
5/16"
17
STEP 19
19
STEP 20
STEP 20
20
STEP 21
21
25
Summary of Contents for R233TC-2
Page 109: ...109 u 109...
Page 168: ...168 K GARANCIJSKI POGOJI y 168...
Page 169: ...169 y 169...
Page 172: ...172...
Page 173: ...173...
Page 174: ...FQ 7 0 0 5 cm 3 7...
Page 175: ...A B C D G E J F H I K L N...