![TECSYSTEM 1MN0143 Instruction Manual Download Page 13](http://html1.mh-extra.com/html/tecsystem/1mn0143/1mn0143_instruction-manual_1073018013.webp)
13
NT539
19
END is displayed
End of programming
20
Press ENT to store the settings and
exit programming
Err: incorrect programming of
the LED values (note 6)
21
Return to step 1
1) The MODE key allows reversing the programming steps.
2) After 1 minute's keyboard inactivity, programming is exited without saving the data.
3) During programming the control unit does not control/protect the monitored machine.
4) At the end of programming the control unit is restarted and the FAULT relay switches until the unit is fully restarted.
5) If pressing ENT,
“Err” appears, it means that one of the following mistakes has been made:
ERR ALL.: ALARM
≥ TRIP (ALARM AND TRIP LEDS FLASHING)
ERR FAN: FAN-OFF
≥ FAN-ON (FAN LED FLASHING)
We recommend you check the unit's programming before starting the device.
The default parameters set by TECSYSTEM might not match your requirements.
Programming the device is the end user's responsibility, the settings of the alarm thresholds and the enabling
of the functions described in this manual must be checked (by a specialized engineer) according to
the application and features of the system where the control unit is installed on.
ATTENTION: