Fixture ID
RDM
With this function you can call up various submenus via RDM.
This device is RDM ready. RDM stands for "Remote Device Management" and makes remote control of
devices connected to the DMX-bus possible. ANSI E1.20-2006 by ESTA specifies the RDM standard as an
extension of the DMX512 protocol.
Manual settings like adjusting the DMX starting address are no longer needed. This is especially useful when
the device is installed in a remote area.
RDM is integrated in DMX without influencing the connections. The RDM-data is transmitted via the standard
XLR-poles 1 and 2 – new DMX-cables are not necessary. RDM ready and conventional DMX devices can be
operated in one DMX line. The RDM protocol sends own packages in the DMX512 data feed and does not
influence conventional devices.
If DMX splitters are used and RDM control is to be used, these splitters must support RDM.
The number and type of RDM parameters depend on the (optional) RDM controller being used.
RDM Parameter ID's (Slot 21-22)
Value
Category _Network Management
DISC_UNIQUE_BRANCH
0x0001
DISC_MUTE
0x0002
DISC_UN_MUTE
0x0003
Category -RDM Information
SUPPORTED_PARAMETERS
0x0050
PARAMETER_DESCRIPTION
0x0051
Category _Product Information
DEVICE_INFO
0x0060
DEVICE_MODEL_DESCRIPTION
0x0080
MANUFACTURER_LABEL
0x0081
DEVICE_LABEL
0x0082
FACTORY_DEFAULTS
0x0090
SOFTWARE_VERSION_LABEL
0x00C0
Category -DMX512 Setup
DMX_PERSONALITY
0x00E0
DMX_PERSONALITY_DESCRIPTION
0x00E1
DMX_START_ADDRESS
0x00F0
SLOT_INFO
0x0120
SLOT_DESCRIPTION
0x0121
Category _Sensors
SENSOR_DEFINITION
0x0200
SENSOR_VALUE
0x0201
Category _Power/Lamp Settings
0x04xx
DEVICE_HOURS
0x0400
Category -Display Settings
DISPLAY_INVERT
0x0500
Category _Configuration
PAN_INVERT
0x0600
TILT_INVERT
0x0601
Category _Control
IDENTIFY_DEVICE
0x1000
RESET_DEVICE
0x1001
Reload Default
With this function you can restore the factory settings of the device. The different settings (marked in the
table) will be set back to the default values (shaded).
Program
Play Slave Revice