background image

If the Meter does not work while the fuse is all right, send it to
your dealer for repair.

C. Replacing the Battery (see figure 12)

To avoid false readings, which could lead to                electric
shock or personal injury, replace the battery as soon as the
battery indicator “  ” appears.

Make sure the test leads are disconnected from the circuit
being tested before opening the case bottom.

To replace the battery:

1.

2.

3.
4.

5.

Press the

POWER

 to turn the Meter off and remove all

connections from the terminals.
Remove the screw from the battery compartment, and
separate the battery compartment from the case bottom.
Remove the battery from the battery compartment.
Replace the battery with a new 9V battery (NEDA1604,
6F22 or 006P)
Rejoin the case bottom and battery compartment, and
reinstall the screw.

Warning

l

If the Meter beeps, the fuse is good.

l

If the display shows

, replace the fuse and test again.

l

If the display shows any other value, have the Meter serviced
and contact your dealer immediately.

(figure 12)

possible

32

Summary of Contents for DMM8060

Page 1: ...ital 3999 l Measurement Speed Updates 3 times second l l Relative Humidity l Altitude Operating 2000 m Storage 10000 m l Battery Type One piece of 9V NEDA1604 or 6F22 or 006P l Battery Deficiency Display l Dimensions HxWxL 177 x 85 x 40 mm l Weight Approximate 300g battery included l Safety Compliances IEC61010 CAT III 1000V CAT IV 600V overvoltage and double insulation standard l Certifications D...

Page 2: ...0Hz 400Hz 400 0 1 1 4k 40k 10 400k 100 4M 1k Accuracy Specifications 1 Remarks Input impedance C Resistance Range Resolution Accuracy Overload Protection 1 2 1 2 2 1 5 2 1000Vp Remarks Open circuit voltage approximate 0 45V 40M 10k Measure at REL mode 1 2 2 B AC Voltage Range Resolution Accuracy Overload Protection 4V 40V 400V 1 5 750V 1V 1 2 5 1000V DC 750V AC rms continuous Remarks l Input imped...

Page 3: ...approximate 1 48V l Displays approximate forward voltage drop reading 0 5V 0 8V F Capacitance Resolution Accuracy Overload Protection Measure at REL mode 3 10 3 5 4 5 1000Vp G Frequency Duty Cycle Range Resolution Accuracy Overload Protection 10Hz 10MHz 0 1 99 9 0 01 1000Vp Remarks l 10Hz 10MHz Range l 0 1 99 9 Reading is only for reference purpose Accuracy Specifications 2 300mV rms input sensiti...

Page 4: ... than 15 minutes I DC Current 0 5A 250V fast type Glass fuse 5x20 mm 10A 250V fast type Glass fuse 5x20 mm Overload Protection Glass fuse 0 5A 250V fast type 5x20mm Remarks Accuracy Specifications 3 400 A 0 1 A l 4A 10A Range 29 H Temperature Model DMM8060 8061 ...

Page 5: ... 5x20 mm Accuracy Specifications 4 J AC Current 400 A 0 1 A 30 and interval not less than 15 minutes Remarks Model DMM8060 displays effective value of sine wave mean value response Model DMM8061 displays true rmsvalue l 4A 10A Range For continuous measurement 10 seconds ...

Page 6: ...cotton bar with detergent as dirt or moisture in the terminals can affect readings l Turn off the power of the Meter when it is not in use and take out the battery when not using for a long time Take out the battery when it is using for a long time l Do not use or store the Meter in a place of humidity high temperature explosive inflammable and strong magnetic B Testing the Fuses fuses with identi...

Page 7: ...3 4 5 Press the POWER to turn the Meter off and remove all connections from the terminals Remove the screw from the battery compartment and separate the battery compartment from the case bottom Remove the battery from the battery compartment Replace the battery with a new 9V battery NEDA1604 6F22 or 006P Rejoin the case bottom and battery compartment and reinstall the screw Warning l If the Meter ...

Page 8: ...tions from the terminals Remove the screw from the battery compartment and separate the battery compartment from the case bottom Remove the 2 rubber feet and 2 screws from the case bottom and separate the case top from the case bottom Remove the fuse by gently prying one end loose then take out the fuse from its bracket Install ONLY replacement fuses with the identical type and specification as fo...

Page 9: ...operation Replacement of the fuses is seldom required Burning of a fuse 6 7 Rejoin the case bottom and case top and reinstall the 2 screws and 2 rubber feet Rejoin the battery compartment and the case top and reinstall the screw 34 ...

Page 10: ...n Female D sub 25 Pin Female Pin Name To useDMM8061 Interface Program you need the following hardware and software l An IBM PC or equivalent computer with 80486 or higher processor and 640 x 480 pixel or better monitor l Microsoft Windows 95 or above l At least 8MB of RAM l At least 8MB free space in hard drive l Can access to a local or a network CD ROM l A free serial port l A mouse or other poi...