16
TS1061 Dual Wiegand Interface Installation Manual
Figure 8 on page 17 consolidates the different connections of a TS1061 Dual
Wiegand Interface into one diagram. It shows an example of using the Interface
to connect to various parts of a door:
• The door’s contact is connected to the first input on the Interface
(Figure 2 on page 8, item 10)
• The door’s egress button, on the other side of the wall, is connected to the
second input on the Interface (Figure 2 on page 8, item 10)
• The door’s card reader is connected to the first set of Wiegand reader
connections (Figure 2 on page 8, item 12)
• The door’s lock is connected to the first relay on the Interface (Figure 2 on
page 8, item 9)
The figure shows references to other figures in this document that provide
additional wiring information.
The figure indicates that a second set of connections (relay, Wiegand reader,
and inputs) can be used for a second door.
The figure also indicates that the Interface is connected to a Challenger
Plus