User’s manual 

10

 

UPS ERA PLUS 900-1.100 

Technology 

Line Interactive with Stabilizer 

Nominal Input Voltage

  

Single-phase 230 Vac 

Input Voltage Range

 

+20% / -25% 

Input/Output Frequency 

50/60 Hz (automatic selection) 

Input Frequency Range

 

+/- 5% 

Nominal Output Voltage

 

Single-phase 230 Vac 

Output Voltage Regulation  
(Normal mode) 

Through AVR (Automatic Voltage Regulation) 

Output Voltage Regulation 
(Battery mode) 

+/- 5% 

Output Inverter Waveform 

Modified Sinewave 

Accepted Overload 

< 130% 

Certifications 

CE  

Standards: CEI EN 62040-1: 2009 (Low Voltage Directive) –  

CEI EN 62040-2: 2006 (EMC Directive) 

Battery Type 

Lead acid, sealed, free maintenance 

Number of batteries 

Nominal Battery Voltage 

12 Vdc 

Battery Specifications 

12 Vdc – 4,5 Ah – 6 cells 

12 Vdc – 7,2 Ah – 6 cells 

Backup Time (typical)  

10 min 

Battery Charge Time (typical) 

4 hours 

Audible Noise (at 1 meter)

 

< 40 dBA 

Cooling 

Natural 

Environmental Operative Specification

 

Temperature: 0-40 °C  - Humidity 0-95% (without condensation)  

Altitude: max 3.000 mt 

Computer Interface 

1 USB port 

UPS Management Software 

Software TecnoManager,  

downloadable free of charge from 

www.tecnoware.com

 

Output sockets 

2 UPS Output sockets (Schuko/Italian type) 

Dimension (W x H x D) 

10,1 x 14,2 x 27,9

 

cm 

Net Weight  

3.7 Kg 

4,5 Kg 

 

Technical data may change without prior notice 

Summary of Contents for ERA PLUS 1.100

Page 1: ...Uninterruptible Power Supply ERA PLUS 900 ERA PLUS 1 100 User s manual...

Page 2: ......

Page 3: ...9 9 Maintenance 11 9 1 UPS Cleaning 11 9 2 Battery 11 9 3 Battery Replacement 11 9 4 Operator Safety 12 10 Troubleshooting 12 Conformity to the European Directives 14 Product Disposal 14 Lead Batteri...

Page 4: ...he batteries they will remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing th...

Page 5: ...ure or a low battery condition directly to a computer this makes it possible to automatically save your data during an extended black out with the most widespread operating systems Windows Mac OS X Li...

Page 6: ...ackaging and carry out a meticulous inspection We recommend keeping the original packaging in a secure place in case you need to send the UPS for maintenance purposes In case of transport damage notif...

Page 7: ...d measurements Front panel shown below consists of two parts 1 The ON OFF button enables the user to turn ON OFF the UPS 2 The LINE BATTERY led this led blue color is always on during the functioning...

Page 8: ...50 V 3 Grounded UPS Output receptacles Schuko Italian type black colour to supply critical loads 4 Computer Interface USB connector it is the communication USB port Only for UPS ERA Plus 1 100 In case...

Page 9: ...g correctly 7 Simulate a black out by removing the AC Input line The UPS starts working in Battery mode the UPS emits a brief acoustic signal every 10 seconds 8 Be sure that all the devices connected...

Page 10: ...seconds and simultaneously the LINE BATTERY led flashes 6 3 Low Battery and Automatic Restart In Battery mode ERA PLUS indicates the Low Battery condition whenever the battery reaches a charge level...

Page 11: ...chapter Technical Characteristics as this may damage the unit In this case the warranty is void 6 5 Fault Condition The UPS indicates the Fault condition by emitting a continuous acoustic alarm During...

Page 12: ...ve CEI EN 62040 2 2006 EMC Directive Battery Type Lead acid sealed free maintenance Number of batteries 1 Nominal Battery Voltage 12 Vdc Battery Specifications 12 Vdc 4 5 Ah 6 cells 12 Vdc 7 2 Ah 6 ce...

Page 13: ...Take in mind that batteries are recharged automatically if the UPS works in Normal mode or if the UPS is off and connected to the AC Input Line Battery life strongly depends on the ambient temperatur...

Page 14: ...afety Whenever the UPS is not responding anymore to original characteristics the UPS must be made non operative and every usage not authorised must be avoided After it will be necessary to refer to qu...

Page 15: ...cal mains Input mains fuse is burnt Replace the fuse with another of the same type Black out conditions surge Over Voltage or Low Voltage Wait until the AC Input Line returns to normal conditions Elec...

Page 16: ...rban waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of the same or of any...

Page 17: ......

Page 18: ......

Page 19: ...TECNOWARE s r l www tecnoware com...

Reviews: