DESCRIPTION
The
204
series is entirely made in AISI316L stainless steel, for use in industrial and marine environments and in general where a
corrosive atmosphere can cause a rapid deterioration of a standard aluminium-steel housing.
MODELS
204-110
Camera housing (L=500 mm). UFW: 110 mm
204SH110
Camera housing (L=500 mm) with sunshield and heater. UFW: 110 mm
204-145
Camera housing (L=500 mm). UFW: 145 mm
204SH145
Camera housing (L=500 mm) with sunshield and heater. UFW: 145 mm
204WW120
Camera housing (L=500 mm) with sunshield, heater and integrated wiper. UFW: 120 mm
204WW140
Camera housing (L=500 mm) with sunshield, heater and integrated wiper. UFW: 140 mm
204IR70
Camera housing (L=500 mm). Shutter optional. UFW: 70 mm.
204SHIR70
Camera housing (L=500 mm) with sunshield and heater. UFW: 70 mm.
204WWIR70
Camera housing (L=500 mm) with sunshield, heater and integrated wiper included. UFW: 70 mm.
204IR110
Camera housing (L=500 mm). UFW: 110 mm.
204SHIR110
Camera housing (L=500 mm) with sunshield and heater. UFW: 110 mm.
204WWIR110
Camera housing (L=500 mm) with sunshield, heater and integrated wiper. UFW: 110 mm.
204IR145
Camera housing (L=500 mm). UFW: 145 mm.
204SHIR145
Camera housing (L=500 mm) with sunshield and heater. UFW: 145 mm.
UFW:
Usable front window diameter
-L
suffix refers to camera housing with L=600 mm.
INSTALLING THE CAMERA
i
Prior to installation and operation, read carefully all instructions the in this manual and heed all warnings.
Unpack this equipment and handle it carefully. If the package appears to be damaged, notify the shipper immediately.
Use the original packaging to transport the unit. Disconnect power supply before moving it. In case of returning the equipment,
the original packaging must be used.
Make sure that the installation surface can support at least four times the weight of the unit in normal operating conditions. In case
of excessive external stress (e.g. vibration, strong winds or impact), the equipment may need additional means of protection.
Proper stainless steel hardware should be carefully chosen to fasten the unit to the surfaces.
Use caution when lifting and assembling the unit. It is recommended that non-slip protective gloves be worn during installation.
The unit could bear sharp edges.
Trying to manually force the wiper will result in damaging the device and will void the warranty.
To maintain the IP rating of the unit, adequate cable glands must be used. The unit must be tightly closed when operating.
For security reasons, do not install the unit in the proximity of water containers and never push objects or pour liquids into the
unit. The unit can be safely used in damp environments or outdoors, as long as the connectors are properly sealed.
Video and data cables should not share the same conduit with supply voltage cables. Whenever EMC is an issue, adequately
shielded cables must be used.
Open only the covers pointed out in this installation manual. Other covers should be open only by the manufacturer.
This equipment has been designed to fit in harsh environments requiring little or no maintenance. Suggested inspection interval is
6 months, but extremely harsh environments may require more frequent inspection and maintenance checks. On each inspection
check the O-ring seals and the eventual window wiper blade integrity. Replace them if necessary.
Check cables, electrical connections and mounting hardware for integrity and tightness. Replace or tighten any damaged/loose
part.
Operating temperature: -20° +55° C (-4° +131° F).
h
Before performing any operation, turn off the power. The installation of the unit can be performed only by qualified personnel in
accordance with the regulations in force. Do not connect the unit to a supply circuit unless the installation is completed.
Check carefully the supply voltage marked on the label. Incorrect Power Supply Voltage may damage the unit. Do not overload
the terminal connection, as it may cause a fire or electrical shock hazard.
An all-pole mains switch with an opening distance between the contacts at least 3 mm in each pole must be incorporated in the
electrical installation. The switch must be equipped with protection against the fault current towards the ground (differential) and
the overcurrent (magnetothermal, maximum 15A). It must be very quickly recognizable and readily accessible. A suitable blow fuse
must also be installed for protection.
For connection to the mains, use a multipolar cable having minimum 3x1,5 mm
2
(15 AWG). The main cable must be at least
protected by an ordinary PVC sheath.
Fasten all the cables inside the housing with cables ties or other fixing means to avoid the electrical contact with surrounding
parts in case that terminal blocks screw off.
Electrical connections (such as plugs and cords) must be protected from potential hazardous environmental factors (e.g. foot
traffic, hitting objects).
Ensure that the unit case is properly earthed, connecting all the earth ground studs. Earth cable should be about 10mm longer
than the other cables on the connector, in such way that it won't be accidentally disconnected if the cable is stretched or pulled.
When leaving the unit unused for long periods, disconnect supply cables.
2