Tecnosystemi Toolsplit TSC200004 User Manual Download Page 2

Sistemi

2

1 - COMPONENTI E SPECIFICHE

N.

Nome

N.

Nome

1

Gancio

9

Manometro bassa pressione

2

Manometro alta pressione

10

Guaina

3

Coperchio

11*

Tubo blu

4

Vite regolazione zero

12*

Tubo giallo

5

Valvola alta pressione

13*

Tubo rosso

6

Visore

7

Valvola bassa pressione

8

Attacco

*

*

 SOLO PER CODICE TSC200004

Summary of Contents for Toolsplit TSC200004

Page 1: ...mero Verde 800 904474 only for Italy e mail info tecnosystemi com C F P IVA R I TV IT02535780247 Cap Soc 5 000 000 00 i v www tecnosystemi com Sistemi KIT GRUPPO MANOMETRICO A DUE VIE CON PROTEZIONE I...

Page 2: ...Gancio 9 Manometro bassa pressione 2 Manometro alta pressione 10 Guaina 3 Coperchio 11 Tubo blu 4 Vite regolazione zero 12 Tubo giallo 5 Valvola alta pressione 13 Tubo rosso 6 Visore 7 Valvola bassa p...

Page 3: ...ssa pressione per 3 5 minuti verificando che il vuoto abbia raggiunto e chiuso entrambe le valvole chiudere quindi la pompa del vuoto 4 2 5 Osservare la pressione sul manometro bassa pressione se la l...

Page 4: ...aver rimosso la lunetta Inserire un cacciavite a punta dritta nella vite di regolazione sulla parte anteriore del manometro 1 6 Pulire le interfacce di collegamento per evitare l ingresso di sostanze...

Page 5: ...nosystemi com C F P IVA R I TV IT02535780247 Cap Soc 5 000 000 00 i v www tecnosystemi com Conditioning utions Air Curtains and Accessories r Heating Instruments Tools Multi Zone Air Control System 2...

Page 6: ...Hi Pressure gauge 10 Sheath 3 Cap 11 Blue hose 4 Zero adjusting screw 12 Yellow hose 5 High pressure valve 13 Red hose 6 Sight glass 7 Low pressure valve 8 Connection Ventilation Solutions Accessorie...

Page 7: ...um reached closed both vales then turn of the vacuum pump 4 2 5 Observe the pressure on the low pressure gauge if the pointer is stick to 1 far 3 to 5 minutes the evacuation of a system is succeed lf...

Page 8: ...on the high presure gauge of the manifold 1 4 Safe goggles and gloves must be worn at all time during the use of the manifold 1 5 The gauges are correctly calibrated at the factory before shipment If...

Page 9: ...defects and refers to the supply of spare parts of any components featuring defects without any compensation interest or claim for damages The warranty does not cover the replacement of components da...

Page 10: ...NOTE 10 Ventilation Solutions Accessories For Heating Instruments Tools Air Control System...

Page 11: ...11 NOTE Ventilation Solutions Accessories For Heating Instruments Tools Air Control System...

Page 12: ...ly Phone 39 0438 500044 Fax 39 0438 501516 email info tecnosystemi com C F P IVA R I TV IT02535780247 Cap Soc 5 000 000 00 i v www tecnosystemi com Accessories for Air Conditioning Ventilation Solutio...