![tecnoswitch CR035VB Manual Download Page 36](http://html1.mh-extra.com/html/tecnoswitch/cr035vb/cr035vb_manual_1072095036.webp)
34
Moving on icon , you can set these function:
10.1 - ON/OFF TEMPERATURE DIFFERENTIAL;
10.2 - TEMPERATURE IN A PROPORTIONAL WAY;
10.3 - CORRECTION OF MEASURED TEMPERATURE;
10.4 - FROST PROTECTION;
10.5 - ANTI-SEIZE PUMP.
The programmable thermostat is supplied with ON-OFF Temperature Regulation with a
Therminal Differential set at 0.3° C.
10.1 ON/OFF TEMPERATURE DIFFERENTIAL
It works ON/OFF. Once a temperature value has been set, the temperature differential is the
difference between this value and the system switch-on or switch-off temperature. For example,
having set a temperature of 20° C and differential of 0.3° C, the system switches on when the
temperature reaches 19.7° C and turns off when it reaches 20.3° C.
TEMPERATURE SETTING