Lock/keypad test
(special function #5)
Enter special function #5.
Enter each key once, starting with key “1”, then “2”, “3”, “4”,… “8”, “9”, “0”. Each key is
acknowledged with a double beep. If a key is not recognized, a long beep is emitted after bad
key pressed and function is aborted.
Lock audit function
(special function #7)
Enter special function #7.
Enter Manager code.
Plug and hold a Dallas audit i-button into the keypad slot to download the “basic audit” file from
the lock board. If download is successfully completed double beep, LED power-off.
If you don’t want to download audit file, by pressing user ID key you get user status:
double beep = active, single beep = deleted, long beep = does not exist.
Enter “0” to exit function.
Notes:
•
This function is available only if more than one user is installed.
Set time delay parameters
(special function #9)
Enter special function #9.
Enter Manager code.
Enter time delay value (from 00 to 99 minutes, 2 digits, 00 disables time delay) and open
window (from 01 to 19 minutes, 2 digits). Double beep.
Enter values again to confirm. Double beep if correct, long beep if confirmation error.
Notes:
•
If Manager is the only installed code, this function is not available.
•
If Manager changes values during time delay, the time delay value may only be increased.
Smaller values will be ignored.
Battery change
A series of signals during opening indicates that the battery is weak and must be replaced.
Only use fresh 9V-ALKALINE batteries from brand name manifacturers like DURACELL
TM
.