I.T.S. Ital Trade Services PT 500 with revolving facing tool & heating mirror Operating Manual
8
WARNING!
You can only place the upper and lower spacers in the same clamps and using the same holes. It is strictly forbidden to put the
spacer in different clamps and in different holes.
1.
Configuration 2 moveable 2 fixed clamps
2.
Not completely close the trolleys
3.
Remove the heating mirror disconnecting device
4.
Lift the spacers as shown in the figure above
5.
By using your hands translate the third clamps as in the figure above
6.
Remove the spacers
7.
Place the spacers between the two central clamps
8.
By using your hands translate the moveable clamps until the clamp reaches the limit stop.
9.
Fix the spacers by pushing them down
10.
Place the heating mirror disconnecting device
11.
To fix the heating mirror disconnecting device open the trolleys
12.
Configuration 3 moveable 1 fixed clamp
To configure the again the machine with 2 moveable clamps you must repeat the procedure above in a reverse sense.
To use a beep-beep inserts reduction
To use a beep-beep reduction, fix it by lightly pushing
the reduction in the direction shown as per figure
aside. As you hear a ‘click’ sound the reduction is
properly fixed.
To remove the beep-beep reduction
To safely remove the beep-beep reduction by means
of a screwdriver turn to left the screw shown in the
figure aside. As soon as the reduction is not anymore
hooked to the clamp you can remove it.
Attention: If you need to use reductions under d. 280mm you must before install the reductions d.
315x500mm - If you need to use reductions under d. 250mm you must before install the reductions d.
315x500mm and 250x315mm.