INSTALLATION

CONSIDERATIONS FOR INSTALLATION

1-

Before  fastening  the  brackets  provided,  establish  the  coordinates  using  the  data  given  in

Table 1,

bearing in mind that they are valid if the operator is at maximum extension minus one

 

centimetre of the available stroke (CD) when the gate is closed to obtain maximum working

 

efficiency.

2-

Data B in the table, with reference to the single values A, are to be considered as values

      (recommended).

3-

To anchor the piston, use the fastening brackets provided.

COORDINATES AND TABLE

TABLE 1

Opening angle

A

B

Cu

90

80

80

160

90

90

180

100

100

200

100

150

250

100

110

110

220

120

120

240

120

100

220

110

130

130

260

140

140

280

150

150

300

90° Available stroke = 400mm

160

160

320

175

175

350

190

190

380

200

200

400

90°

stroke

 600 mm

300

300

600

Note1: A+B = C

U

(Stroke used) C

D

= (Available stroke)= 300 mm /400 mm /600mm

·

The installation and testing operations must be performed solely by qualified personnel in
order toguarantee the proper and safe operation of the automatic gate.

· 

The company declines any responsibility for damage caused by incorrect installations due

to incompetence and/or negligence.

·

Before assembling the automatism, check that the gate is in perfect working order, hangs
well on its hinges  and is suitably lubricated. It must also comply with the safety standards
in force in the country of installation..

1.

  Establish coordinates

A + B

 that are

 

to be used.

2. Note:

 The stroke used

 (CU)

 of the

 

operator must never be equal or

 

greater than the available stroke 

CD

3.

   The sum of coordinates

 A + B,

 

establishes the stroke us

 

e

  

d

   CU.

Summary of Contents for BOB

Page 1: ...ve EEC 89 336 92 31 93 68 D L 04 12 1992 N 476 Our products if installed by qualified personnel capable to evaluate risks comply with norms UNI EN 12453 EN 12445 BOB T A TECNO AUTOMAZIONE S R L Via Vicinale snc 03018 Paliano FR Italy 39 0775 533677 39 06 97625593 FAX 39 0775 533299 39 339 5877324 tecnoautomation com tecnoautomation ...

Page 2: ... TECHNICAL DATA 3 DIMENSIONS 4 TYPICAL CONNECTION AND CABLE SECTION 4 CONSIDERATIONS FOR INSTALLATION 5 INSTALLATION 5 6 7 SAFETY PRECAUTIONS PACKING CONTENTS 1 OPERATOR 1 KIT FASTENING PLATES AND RELATIVE ACCESSORIES 1 UNLOCKING KEY 1 CONDENSER 230Vca BOB tecnoautomation ...

Page 3: ...ime 90 Rod stroke Force of thrust motor current input 2 5 VIEW OF TYPICAL AUTOMATION AND NAMES OF COMPONENTS 1 Operator 2 External photocell 3 Flashing warning light 4 Antenna Optimal installation 4 3 1 1 5 5 Internal photocell 6 Electronic control unit 7 Key switch 8 Remote control 6 7 8 250 Kg 1 80 300 2 50 400 3 50 600 mt 230 Vac 250 W 800 12 5 µF 20 C 55 C 7 5 Kg IP 55 15 25 30 sec 300 400 600...

Page 4: ...ONNECTION AND CABLE SECTION 2X1 5mm2 12 Vdc 4X1 5mm2 230 Vca 2X0 75mm2 4X0 75mm2 4X0 75mm2 RX Photocell TX Photocell 2X0 75mm2 3X1 5mm2 230V Line 95 mm 280 mm 330 mm 375 475 675 mm 300 400 600 mm 95 mm BOB tecnoautomation ...

Page 5: ...vailable stroke 400mm 160 160 320 175 175 350 190 190 380 200 200 400 90 stroke 600 mm 300 300 600 Note1 A B CU Stroke used CD Available stroke 300 mm 400 mm 600mm The installation and testing operations must be performed solely by qualified personnel in order toguarantee the proper and safe operation of the automatic gate The company declines any responsibility for damage caused by incorrect insta...

Page 6: ...ling the anchor plate on the piston to the gate Release procedure Open the plug located underneath on the lower part of the piston insert the key provided and turn clockwise FIG 2 FIG 3 FIG 1 FIG 4 1 Fit the anchor plate onto the piston fig 4 2 Close the gate 3 Move the piston with the plate already fitted towards the gate 4 Move the fitting to limit stop then move it back by approximately 1 cm and m...

Page 7: ...d or differential switch suitable for the product and conforming to current standards The manufacturer declines any and all responsibility for product integrity safety and operation in the event incompatible devices and or components are installed Solely original spare parts should be used for repairs and replacements The installer must provide all the information relating to the operation maintena...