TP-8000 Programming Manual
15
Lead In Delay Time: The delay time from the time requesting DTMF ID generation to the time the
first signal happens.
1.10.3 PSC
Controls setup of Power Save Control (PSC) to reduce battery current consumption.
Enable Check box: Check to enable PSC.
PSC On Time: The time when reception part is ON during PSC operation.
PSC Off Time: The time when reception part is OFF during PSC operation.
PSC Active Time: The time that PSC operates after transmission or reception finishes or channel
changes.
1.10.4 TOT
Controls setup of Time Out Timer (TOT) that prohibits continual transmission. When TOT is used,
transmitting ceases if it exceeds time inputted.
Enable Check box: Check to enable TOT.
TX Time Out Time: Inputs the maximum time for one time transmission.
TX Penalty Time: The prohibition time to transmit when transmission time exceeds time out time.
1.10.5 VOX
Controls setup of VOX (voice actuation) which enables transmission by voice signal through microphone
without PTT.
Enable Check box: Check to enable VOX function.
VOX Sensitivity: To set transmission sensitivity on input signal.
VOX Off Time: When VOX is activated, this sets transmission stopping time after no voice input.
Reference: VOX Sensitivity means not signal size of voice input into MIC but level difference between
sampling data of input signal.
1.10.6 Scrambler Inversion Frequency
Controls setup of frequency input to use during security call (Default Standard 3300Hz)