S.p.A.
ITEM TE550
Instruction manual
91/92
15.3 -
PROGRAMMING ERRORS
MESSAGE
NUM
CAUSE REMEDY
WORKING MODE ENE
MIN TIME > MAX
200
During a work cycle in CONTROL
MODE ENE, the minimum weld time
is higher than the maximum weld
time.
Modify the parameter that
triggered the error.
CURRENT MIN LIMIT
> CURRENT MAX LIMIT
201
The value set in CURR MIN is higher
than the value set in CURR MAX.
Modify the parameter that
triggered the error.
DEGREES MIN LIMIT
> DEGREES MAX LIMIT
202
The value set in ANGLE MIN is
higher than the value set in ANGLE
MAX.
Modify the parameter that
triggered the error.
TOTAL PULSE WELDS
> WELD MAX TIME
203
The number of impulses IMPULSE
N. multiplied by the WELD time make
up a number of cycles higher than
the maximum admissible number.
Modify the parameter that
triggered the error.
NOT PROGRAMMABLE
TIP-DRESS. ENABLED
204
The user attempted to enter the
STEPPER MENU while the TIP-
DRESSING function was active. This
situation is incompatible.
Deactivate the TIP-
DRESSING function to
activate the STEPPER
MENU function.
NOT PROGRAMMABLE
STEPPER ENABLED
205
The user attempted to enter the TIP-
DRESSING MENU while the
STEPPER MENU function was
active. This situation is incompatible.
Deactivate the STEPPER
MENU function to activate
the TIP-DRESSING
function.
CURRENT PARAMETER
HIGHER THAN RANGE
206
The required work program contains
the CURRENT parameter the value
of which is higher than the
AMMETER CAP parameter.
Modify the parameter that
triggered the error.
OFFSET DRESSING %
HIGHER THAN STEPPER
207
The DRESSING OFFSET parameter
is higher than the required
DRESSING STEPS increment value.
Modify the parameter that
triggered the error.
CURRENT MAX LIMIT
HIGHER THAN RANGE
208
The required work program contains
the CURR. MAX parameter the value
of which is higher than the
AMMETER CAP parameter.
Modify the parameter that
triggered the error.
THICKNESS MIN LIMIT
> THICK MAX LIMIT
209
The value set in parameter THICK.
MIN is greater than the value set in
THICK. MAX.
Modify the parameter that
triggered the error.
IDENT MIN LIMIT
> IDENT MAX LIMIT
210
The value set in parameter IDENT.
MIN is greater than the value set in
IDENT. MAX.
Modify the parameter that
triggered the error.
NON PROGRAMMABLE
SEAM MODE ENABLED
211
One tried to activate either BUTT
WELD or HIGH SPEED while SEAM
was activated. This is incompatibile.
Deactivate SEAM to
activate either BUTT WELD
or HIGH SPEED.
NON PROGRAMMABLE
BUTT WELD ENABLED
212
One tried to activate either SEAM or
HIGHT SPEED while BUTT WELD
was activated. This is incompatible.
Deactivate BUTT WELD to
activate either SEAM or
HIGH SPEED.
NON PROGRAMMABLE
SERIAL SPOT ENABLED
213
One tried to activate either SEAM or
BUTT WELD while HIGH SPEED
was activated. This is incompatible.
Deactivate HIGH SPEED to
activate either SEAM or
BUTT WELD.
PRESS. MIN LIMIT
>= PRESS. MAX LIMIT
214
The value set to PRES. MIN is
greater or equal to the value set to
PRES. MAX.
Modify the parameter
generating the error.