5.3- Movement
The projector has a maximum movement of 540° for Pan and 270° for Tilt. DO NOT place any
obstructions in the path of the projector's movement.
5.4- Risk of fire
Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended
distance from flammable material is 1 MT.
Minimum distance from the object being illuminated is 2 MT.
5.5- Forced ventilation
You will note, on inspection, that the unit features various air inlets and cooling fans located on both the
base and head of the fixture. These should, under no circumstances, be blocked or obstructed whilst the
projector is in operation.
Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.
5.6- Ambient temperature
The projector should never be installed in places that lack a constant air flow. The ambient temperature
should NOT exceed 40°C.
6- MAINS CONNECTION
Wash 575 with electronic ballast operate at 90-245 VOLT 50-60 Hz.
Wash 575 with electromagnetic ballast operate at 230 VOLT 50-60 Hz
Prior to connecting the unit to your mains supply,
ensure that the model in your possession correctly matches
the mains supply available. For connection purposes,
ensure that your plug is capable of supporting 6,3 amps at 208-230V,
or16 amps at 100-120 V
Strict adherence to regulatory norms is strongly recommended.
6.1- Protection
The use of a thermal magnetic circuit breaker is recommended for each XR 8.
A good earth connection is essential for the correct operation of the projector.
7- DMX SIGNAL CONNECTION
The unit operates using the digital DMX 512 (1990) signal. Connection between the mixer and the
projector or between projectors must be carried out using a two pair screened ø 0.5 mm cable and a
CANNON XLR 5 or 3 pins connector.
(On request: 100 V 50-60 Hz /120 V 60 HZ / 208 V 60 Hz)
8
540°
270°
Electronic ballast
90-245V 50 / 60Hz
Electromagnetic ballast
230 V 50/60 Hz (standard)
On request: 100 V 50-60 Hz
120 V 60 HZ / 208 V 60 Hz
Wash 575 tm3