Adapter receptor (Molex 10 pol.)
TL = learn button
TS = button start
LED1 learn red
LED2 force yellow
LED3 start green
Instant stop - input potential-free = 8
free = 9
Instant stop - output potential-free = 7
Light barrier jumper = 6
Light barrier jumper 0 V earth = 5
24 V DC unstable / 80 mA = 4
Start/stop 0 V earth = 2
Start/stop push-button potential-free = 1
24 V DC unstable / 80 mA = 3
TS
TL
TF
TF = Radio signal button
D
RL
GL
7
65
43
21
9
8
-
+
2-wire light barrier
1
Press
TL
5 sec. until
yellow
LED lights permanently.
4
5
Attention: Any mistakes pressing the buttons can only be deleted by switching off
and pulling out the 230 V plug.
Press
TS
and maintain pressed until
red
and
yellow
LEDs begins
to flash and
green
LED lights permanently.
Press
TL
briefly until
red
and
yellow
LEDs turns off.
The green LED will stay lit as long as
TL
is pressed. Confirm factory setting.
Attention! Before connecting or disconnecting any supplementary modules, receivers,
counters or jumpers, switch off the power supply and pull out the plug!
2
Press
TL
5 sec. until
red
LED lights permanently.
3
Press
TL
5 sec. again until
yellow
LED begins to flash.
Now press
TL
3 times briefly until
red
and
yellow
LEDs begins to flash.
ON
ON
=
complete
OFF
=
partial opening
30 reverting to factory settings
Subject to technical modifications without prior notice.
TP-20.1 u. 30.1-07/13
Attention: Any mistakes pressing the buttons can only be deleted by
switching off and pulling out the 230 V plug.