TECHVIEW LA5597 Operation Manual Download Page 6

LA5597 IR Transmitter Operation Manual 

                                                               

 

- 6 - 

5.0- How to enter to Test mode 

    

You can test the two IR signals which you had learnt into   

the transmitter. Test mode last out 15 seconds. 

i.

 

Pressing TEST button for 3 seconds, the led flashing   

orange indicates enter to test mode.   

ii.

 

Pressing the TEST button once the IR transmitter transmits the A IR signal.   

iii.

 

Going on to press once the test button, IR transmitter transmits the B IR signal. 

IR A signal and IR B signal transmit alternately through pressing test button. 

 

6.0- How to clear the all record signal 

 

i.

 

Power off the IR transmitter. 

ii.

 

Press the LEARN button and power up the   

transmitter. 

iii.

 

After 5 seconds, the  green LED flashing two times indicates all the record signal had 

been cleared. 

 

Section 2 – Troubleshooting Guide 

Wireless IR Transmitter 

Symptoms 

Possible causes and cures 

IR Transmitter can’t learn IR signal from 

remote control. 

Ensure the IR led of remote control front to front the IR 

receiver of the IR transmitter. 

IR Transmitter can not control the IR 

device after learning IR signal. 

Ensure  the position of IR device (TV, Air condition etc) 

would not beyond control distance  of IR transmitter (10 

meters). 

IR Transmitter can not control the IR 

device after learning IR signal. 

Ensure there is no covering in front of the IR receiver of IR 

device(TV, Air condition etc) 

 

 

 

 

 

 

Press 

LEARN 

button for 5 seconds 

Green

 LED flash 

two times 

Press 

TEST

 

button

 

for 3 seconds 

Orange

 LED flash 

Summary of Contents for LA5597

Page 1: ...ic curtain etc Its wireless communication is stable fast and it does not need any wire Installing it you just need to bind relevant IR controlled devices It is very convenient 1 0 System Feature Learn...

Page 2: ...ndicating learn mode for IR signal B Note 1 To complete the whole learning process of a signal once a time 2 If no operation on the button system within 15 seconds will exit learn mode automatically i...

Page 3: ...be selected other output device number Then press SET to go into setup output device 1 function Rotate SET to select Device Type Then press SET to go into Output Device Type function LCD display curre...

Page 4: ...ight off indicate control panel A signal had been learnt and exit to normal mode Operating Home Automation Controller as follow Pressing SET key Controller will transmit learn data to output device To...

Page 5: ...unction and Rotate SET key to select Out_Device Test Press SET go into test output device function and rotate SET to select will test device Press SET to accept and the toggle test outputs ON The corr...

Page 6: ...up the transmitter iii After 5 seconds the green LED flashing two times indicates all the record signal had been cleared Section 2 Troubleshooting Guide Wireless IR Transmitter Symptoms Possible cause...

Page 7: ...eless IR transmitter Double color LED Learn mode Test Mode and Transmission indication IR LED 38K Hz IR transmitter range 10 meters Transmission Frequency AM 433MHz Wireless Transmission Range 100 met...