The
Loca on
of
the
Techtanium
heater:
Locate
the
heater
so
that
there
is
easy
access
to
the
control,
piping,
valves,
drain
and
heater
for
future
servicing
and
maintenance.
The
heater
is
to
be
kept
in
an
area
where
it
is
not
exposed
to
freezing
tem
‐
peratures.
Also,
the
heater
must
be
located
in
an
area
where
a
leak
(eg.
from
the
piping
or
fi
ngs,
from
any
tem
‐
perature
and
relief
valve
discharge,
or
from
the
tank
itself),
will
not
cause
personal
harm
or
dam
‐
age
the
surrounding
area.
The
tank
should
be
installed
in
an
area
with
a
fl
oor
drain
or
in
a
pan
suitable
for
water
heaters.
Read
the
Installa on
and
Opera ng
Instruc ons
manual
thoroughly.
Follow
recommended
piping
and
wiring
diagrams.
Upon
comple ng
installa on,
fi
ll
the
tank
with
water.
While
fi
lling
it
leave
a
hot
water
faucet
open
un l
a
steady
stream
of
water
is
fl
owing.
Then,
shut
the
faucet
and
check
for
any
leaks
throughout
the
en re
system.
The
Tank
should
be
installed
in
an
area
with
a
fl
oor
drain
or
in
a
pan
suitable
for
water
heaters.
DHT
will
not
be
held
liable
for
any
damages
caused
by
water
leakage.
The
fl
oor
or
area
where
the
tank
is
installed
must
be
capable
of
suppor ng
the
tank
when
fi
lled
with
water.
(Refer
to
the
Speci
fi
ca ons
Table
on
the
page
3)
FOR YOUR SAFETY: Do not store or use gasoline or other
fl
ammable vapors or liquids in the vicinity of
this or any other appliance. Controls on this appliance could ignite vapors causing an explosion.
IV Installation & Piping
General:
a.
All
plumbing
must
be
in
accordance
with
the
requirements
of
the
authority
having
jurisdic on.
b.
Use
both
thread
tape
and
pipe
dope
on
all
mechanical
connec ons.
c.
Zone
valve
(if
used)
and
circulator
must
be
sized
to
provide
minimum
fl
ow
rate
speci
fi
ed
in
the
table
to
the
right,
Flow
Speci
fi
ca ons.
Use
1
inch
nominal
copper
tubing
for
fl
ows
greater
than
7
GPM
be
‐
tween
the
boiler
and
heat
exchanger.
See
the
tables
on
Fric on
Loss.
Point
of
emphasis:
using
a
zone
valve
without
a
full
bore
may
cause
high
pressure
drop
which
will
adversely
a
ff
ect
performance.
Use
extreme
care
when
selec ng
zone
valve.
d.
All
piping
must
be
adequately
supported.
e.
Allow
for
thermal
expansion.
f.
Dielectric
Unions
(recommended)
‐
used
to
electrically
isolate
the
Techtanium
tank
from
the
connect
‐
ed
domes c
water
piping.
This
helps
to
minimize
the
possibility
of
corrosion
damage.
8