Electrical & Gas Requirements 

Electrical Requirements 

Check your national and local codes 

regarding this unit. This range require-

s120VAC/60 Hz; 4 ft. (121.9 cm), 3-wire 

cord with grounded 3-prong plug atta-

ched to unit. See “Electrical Connection” 

section for grounding instructions. Must 

be fused seperately from any other 

circuit.

Gas Connection

The appliance must be disconnected from 

the gas supply piping system during any 

pressure testing of that system.

The gas supply (service) line must be the 

same size or greater than the inlet line of 

the appliance. This range uses a 1/2” (1.3 

cm) IDNPT (Sch40) inlet. Sealant on all 

pipe joints must be resistive to LP gas.

The range is designed specifically for 

natural gas or liquid propane (LP) 

gas. Before beginning installation 

verify that the model is compatible 

with the intended gas supply.

Manual shut-off valve:

This installer-supplied valve must be 

installed in the gas service line before 

the appliance in the gas stream and in a 

location where it can be reached quickly 

in the event of an emergency. Any opeing 

behind the range shall be sealed.

In Massachusetts: 

A “T” handle 

type manual valve must be installed in the 

gas supply line to the appliance.

IMPORTANT: Any conversion 

required must be performed by 

your dealer or a qualified licensed 

plumber or gas service company. 

Please provide the service person with 

this manual before work begins.

Pressure Regulator

•All ranges have a pressure regulator on 

the incoming service line for safe and 

efficient operation, since service pressure 

may fluctuate with local demand. 

External regulators are not required on 

this range since a regulator is supplied 

with each unit. Under no condition by-

pass this regulator.

•Manifold pressure should be checked 

with a manometer, natural gas requires 

4.0”W.C.P. and LP gas requires 11.0” 

W.C.P.  Incoming line pressure upstream 

from the regulator must be 1” W.C.P. 

higher than the 

manifold pressure in order to check the 

regulator. The regulator used on this 

range can withstand a 

maximum input pressure of 1/2” PSI 

(14.0” W.C.P.). If the line pressure is in 

excess of that amount, a step down regu-

lator will be required.

 

 

WARNING

ELECTRICAL SHOCK

HAZARD

To avoid the risk of electri-

cal shock, personal injury or 

death; verify 

electrical power is turned off at the 

breaker box and gas supply is turned off 

until the range is installed and ready to 

operate, installation by an authorized 

installer only.

Summary of Contents for Superiore RN362GPSS

Page 1: ...461308462 07 2015 INSTALLATION MANUAL FOR 30 AND 36 GAS RANGES...

Page 2: ...USA 23 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHATTO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any e...

Page 3: ...wn to the State of California to cause cancer and birth defects or other reproductive harm California law requires this warning to be given to customers in the State of California An air curtain or ot...

Page 4: ...uit no other receptacles switches or loads in the circuit Connected to a standard breaker of appropriate size GFI breaker of the same size NOT recommended Rated for Class A 5 mA 1 mA trip current as p...

Page 5: ...r death verify your appliance has been properly grounded in accordance with local codes or in absence of codes with the National Electrical Code NEC ANSI NFPA 70 latest edition WARNING WARNING DANGER...

Page 6: ...imensions 30 Gas Ranges Note Unit shown with island trim Note All gas ranges are equipped with spacer on the back 25 64 to prevent over heating of the wall 29 7 8 23 2 2 3 16 35 7 8 min 37 5 16 max 1...

Page 7: ...30 Gas Ranges 2 25 2 2 1 1 2 5 Gas 33 1 11 32 2 6 8 1 3 8 29 7 8 29 7 8 3 8 Electricity 2 1 8 5 5 9 16 35 7 8 min 37 5 16 max 26 7 8 2 3 8 3 8 23 2 3 16 2 1 8 1 11 32 35 15 32 min 36 7 8 max 2 6 8 min...

Page 8: ...ensions 36 Gas Ranges Note Unit shown with island trim Note All gas ranges are equipped with spacer on the back 25 64 to prevent over heating of the wall 35 7 8 min 37 5 16 max 35 7 8 23 2 33 2 3 16 1...

Page 9: ...6 Gas Ranges 35 7 8 min 37 5 16 max 2 2 33 35 7 8 2 1 8 25 2 2 Gas 1 3 8 35 7 8 Electricity 5 5 9 16 1 1 2 5 1 11 32 2 6 8 3 8 26 7 8 2 3 8 3 8 23 2 3 16 2 1 8 1 11 32 35 15 32 min 36 7 8 max 2 6 8 mi...

Page 10: ...t Interior dimensions 2413 64 x 1957 64 x 2031 64 Burners injectors and volume ranges 36 mod 361 and 362 Natural 4 LP Propane11 By pass Inj W BTU h Inj W BTU h W BTU h Small burner 92 1055 3600 56 105...

Page 11: ...ximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 6 15 2 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop Wall cabinets above the range must be a minim...

Page 12: ...efer to the range hood installation instructions for additional information These dimensions provide for safe and efficient operation of the hood Important There must be a minimum of 6 15 2 cm clearan...

Page 13: ...husetts A T handle type manual valve must be installed in the gas supply line to the appliance IMPORTANT Any conversion required must be performed by your dealer or a qualified licensed plumber or gas...

Page 14: ...ressure regulator 3 Screw the assembled pressure regu lator on the range like shown on picture below Pay attention to the vertical aligne ment of the same pressure regulator Gas Requirements 4 Re inst...

Page 15: ...fied flexible connector or at least1 2 1 3 cm ID NPT with suitable strainreliefs in compliance with ANSI Z21 41and Z21 69 G area for gas connection E area for electric connection In Canada CAN 1 6 10...

Page 16: ...rinted on the body Consult the table on Specifications Technical data paragraph for matching nozzles to burners Save the nozzles removed from the range for future use STEP1 PRESSURE REGULATOR The pres...

Page 17: ...d on the body Consult the table on Specifications Technical data paragraph for matching nozzles to burners STEP 3 MAIN OVEN BURNER To replace the nozzles of the main oven burner start by removing the...

Page 18: ...2 screws on left and right sides and pull out the burner from its support burner from its support ATTENTION pay extra attention to avoid damage to the igniter and thermocouple For range 30 Using a 7 m...

Page 19: ...and proceed to setting the minimum for each burner Gas Requirements STEP 6 MINIMUM FLAME ADJUSTMENT WARNING These adjustments should be made only for use of the appliance with natural gas For use wit...

Page 20: ...nutes 3 Set the knob to the MINIMUM setting 4 Remove the knob 5 With a slotted screwdriver turn the choking screw bypass screw at the left side of the thermostat bar and while observing the flame at t...

Page 21: ...and must be installed with the unit Refer to An ti tip Device Installation section Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior should be washed...

Page 22: ...must be done by your dealer a qualified licensed plumber or certified gas installer Door Removal 1 Open the door completely Place the pins supplied with unit in pin hole For personal safety ONLY use p...

Page 23: ...contai ner situated over the appliance Before installing the legs position the appliance near its final location as the legs are not suitable for moving the appliance over long distances After unpack...

Page 24: ...th the installation instructions in this document Device must be engaged properly to prevent product from tipping over Anti tip Device Installation Measure from floor to the anti tip bar located in a...

Page 25: ...ation always check for gas leaks with soapy water solution DO NOT USE AN OPEN FLAMETO CHECK FOR GAS LEAKS Connect gas and electrical Before placing appliance in operation always check for gas leaks Th...

Page 26: ...scrape stainless steel Scratches arealmost impossible to remove Performance Checklist A qualified installer should carry out the following checks Check top burner ignition Push and turn the knob Full...

Page 27: ...ratures Broil Broil Gas oven switch knob range 36 OFF Closed position from MIN to MAX 300 500 F Oven temperatures Broil Broil OFF Closed position Full on position internal ring Full on position estern...

Page 28: ...write to CUSTOMERCARE TECNOSPA IT Record the information indicated below You will need it if service is ever required The model and serial number can be found by looking in the last page of this book...

Page 29: ...ll labor and in home service to repair or replace the defective part This warranty is extended to the original purchaser and any succeeding owner with proper documentation of ownership for products pu...

Page 30: ...acts of God 16 Expenses for travel and transportation to locations more than 30 miles from an authorized TECNOGAS SUPERIORE retailer 17 Products with original serial numbers that have been removed The...

Page 31: ...31 461308462 07 2015 Electric diagram 30...

Page 32: ...32 Electric diagram 36 6 burners...

Page 33: ...33 461308462 07 2015 Electric diagram 36 4 burners griddle...

Page 34: ...34 INSTALLATION LABEL CONVERSION LABEL Labels...

Page 35: ...35 461308462 07 2015...

Page 36: ...tecnogassuperiore us...

Reviews: