UPS ERA LED 1.5 – 2-0 – 2.6
7
User’s manual
4.2
Rear Side
Figure 2 – Rear Side
1.
Grounded AC Input power socket:
IEC C14 type; to connect the UPS to the AC utility line.
2.
Input fuse:
electrical specification: max current 10 A (ERA LED 1.5 – 2-0 -2.6), voltage 250 V.
3.
Grounded UPS Output receptacles:
IEC C13 type, black colour, to supply critical loads.
4.
Grounded (ONLY FILTERED) Output receptacles:
IEC C13 type, red colour, to supply NON-critical loads.
5.
Telephone protection (RJ11/RJ45 IN/OUT connectors):
to protect and filter a phone line, an ADSL or a LAN
(TNV-3 type connections).
6.
Computer Interface (USB connector
)
:
it is the communication USB port.
The 2 ONLY FILTERED Output receptacles (red colour, #4), protect only the devices
connected from overvoltages and disturbances of the AC line. Please connect ONLY the
NON-critical devices to the ONLY FILTERED Output receptacles
In case of anomaly to the AC line (black-out), ONLY the UPS Output receptacles (black
colour, #3) continue supplying the correct power to all connected equipment. Please
connect all the non-critical devices to the UPS Output receptacles.