![TechnoVap CARMEN PLUS INOX Using Instruction Download Page 9](http://html.mh-extra.com/html/technovap/carmen-plus-inox/carmen-plus-inox_using-instruction_1070731009.webp)
9
(d) If using detergent please follow the specific instructions: 1/3 liter detergent for every 3 liters
water (about 10% is the detergent percentage), making sure to fill in first the detergent to obtain
a better mixing.
(e) Insert the plug (22) into an electrical outlet, making sure that the voltage and the amperage correspond
with those printed near the handlebar on the machine.
WARNING
WHEN THE WATER TANK IS EMPTY WITH THE LOW WATER INDICATOR (11) ON, ADD WATER
(MAX. 3 LITERS) TO THE WATER TANK (16).
PLEASE NOTE: THIS OPERATION CAN BE CARRIED OUT WITHOUT SWITCHING OFF THE
MACHINE.
Refilling of detergent:
Once the detergent tank is empty, proceed as following:
1. Add detergent and water in the detergent tank (15).
2. Activate the steam adjustment switch (36) on minimum steam position while pushing the detergent
switch (35) and the steam command switch (34) until detergent is coming out of the accessory.
3. The machine is now ready for use.
OPERATING THE CARMEN PLUS INOX WITH KIT RADAMES
Insert the vacuum hose (30) into vacuum hose outlet (6) and the steam plug (32) into the steam outlet (23)
found on the front of the machine. Push until the latches (5 and 31) lock into place.
Activate the power switch (8) and the boiler switch (9) in for the production of steam and wait
approximately 4 minutes until the green "ready steam" indicator (10) on the command switch lights up
indicating the boiler has reached operating pressure. The switches (36,37 and 38) located on the handle
should be in OFF position.
Positioning the switches (36 and 37) on the handgrip will regulate the steam flow as follows: switch (36)
minimum flow, switch (37) medium flow, switches (36) and (37) maximum flow. Use the steam command
switch (34) to activate the steam flow.
The vacuum switch (38) activates the vacuum and can be used simultaneously with steam.
The detergent switch (35) enables you to inject detergent with the steam by activating it for a few seconds
at a time to avoid exceeding the injected liquid to the steam.
To clean with the combination of steam, injection of detergent and vacuum suction choose the accessory
best suited for the job:
The multi-purpose floor tool (51): with appropriate inserts (53 and 54). Inserts are locked into place by
sliding the latches (52) to the OPEN position and hold the insert in place applying a little pressure while
sliding the latches in BLOK position. Remember that the command switches on the handle (36-38) must be
on OFF position.