Annex A SPN of MasterCAN DAC Functional modules / Digital-to-analog gate DAC15
FM
MasterCAN DAC J1939 i/o modules. Operation manual. Version 2.0
©
Technoton, 2018
47
A.2 Digital-to-analog gate DAC15 FM
Digital-to-Analog Gate DAC15 FM
—
is designed to receive digital data of
CAN j1939/S6 Telematics interface
, to convert
parameters into analog signals of
different types (voltage, frequency, pulse, current, discrete, resistive) and transmit them to
the respective Unit outputs.
*
This FM is created only for MasterCAN DAC15 model.
Figure A.2
—
Window of settings of Digital-to-analog gate DAC15 FM
in Service S6 MasterCAN software
Figure A.3
—
Pulse output settings
Table A.2
—
Digital-to-analog gate DAC15 FM.
SPNs, displayed and/or editable in Service S6 MasterCAN software
SPN
Name
Factory
value*
Unit
of measure
Data Range
Clarification
Outputs settings (
Output
number
No
No
0…255
Choosing Unit’s contact group O1 of
analog/frequency
physical output.
PGN
Electronic engine
controller 1
No
0…65535
Specifying input data of PGN, from which SPN parameter
should be chosen for analog/frequency signal
conversion.
PGN can be selected in Software from the priority list
containing the most important Vehicle parameters or
from extended list of
SPN
Engine
speed
No
0…524287
Selecting SPN which should be converted to
analog/frequency signal from the group of parameters of
specified PGN.