MasterCAN DAC connection / Connecting analog outputs
MasterCAN DAC J1939 i/o modules. Operation manual. Version 2.0
©
Technoton, 2018
28
2.6 Connecting analog outputs
1) Analog outputs of MasterCAN DAC15
are connected to:
•
Signal wires of analog voltage/frequency/pulse signal, in compliance with the colour
of the wires and the designation of contacts of
IN/OUT
connector
(see table 11);
•
Current/discrete/resistive signal wires, in compliance with the colour of the wires and
the designation of contacts of
OUT
connector (see table 12).
Table 11
—
Connection of MasterCAN DAC15 analog output (
IN/OUT
connector)
Connector
Pinout
Connector
Contact
Number
Wire
Marking
Contact
group
Wire
Color
Circuit
Designation
Signal
Parameters
3
AFout+
O1
Red
Analog/
frequency
output
See
(table
3)
1
AFout-
Brown
Analog/
frequency/pulse
output
Table 12
—
Connection of MasterCAN DAC15 analog outputs (
OUT
connector)
Connector
Pinout
Connector
Contact
Number
Wire
Marking
Contact
group
Wire
Color
Circuit
Designation
Signal
Parameters
1
Iout-
O2
Brown
Current
output
See
(table
3)
5
Iout+
Red
2
D1GND
O3
Brown
Discrete
output
6
D1+
Red
3
D2GND
O4
Brown
Discrete
output
7
D2+
Red
4
Rout-
O5
Brown
Resistive
output
8
Rout+
Red