8
Manual TT-KS
GB
3.3 Radio frequency – wired versions model E4
The regulation of the desired
room temperature implements
a built-in temperature control
device.
position 0 : OFF
position 1 : approx. 5°C (frost
protection)
position 4 : approx. 20°C
position 6 : approx 30°C
An illuminated display indicates
the heating process of the
radiator.
CAUTION
- After completion of works all electrical connections should be
tested for
tightness. Additionally an electrical safety check should be carried
out ie: short circuit, earth
continuity, resistance to earth and polarity check
and all the relevant test certificates
produced.
3.4 Radio frequency – RF models
All Radio Frequency radiators come complete with a pre-wired TRF Receiver which is
controlled by either the TPF or TZF control.
TPF transmitter installation
a
Follow the instructions outlined on page 27 for single radiator installations according
to the instructions included in the TPF transmitter packaging.
b
Locate the TPF programmer on a suitable wall in the same room as the
radiator.
TBF digital transmitter installations
a
Follow the information according the instruction in the TBF packaging.
b
Locate the TBF digital room thermostat on a suitable wall in the same room
as the radiator.
c
Configure the TBF digital room thermostat and TRF receiver located on the
radiator according to the instructions included in the TBF
packaging.
d
Set the required temperature by adjusting the +/- buttons.