Electrical Connection 

 

The ISP heating panel is equipped plug. 

 

It is always a residual current circuit breaker for use with an operating current of 30 mA maximum. If the 

supply cord of this appliance consumption is damaged, it must be replaced by the manufacturer or a 

service technician.

 

 

Operation of the ISP heating panels

 

 

It is recommended that the control of the ISP heating panels by an external room thermostat from 

TECHNOTHERM (eg. radio receiver TPF or with the digital radio transmitter TBF. In addition, the ISP 

heating panels are equipped with a limiting thermostat to ensure their safe 

 

 

WARNING: DO NOT COVER THE HEATER 

 

 

 

 

Technical data: 

model width  

690 mm 

power 
[Watt] 

W x H x D [mm] 

weight 

Model width  

690 mm 

power 
[Watt] 

W x H x D [mm] 

weight 

Design-W/B/M 350 

350 

730 x 690 x 20 

14,8 

Design-W/B/M 350 RF 

350 

730 x 690 x 20 

14,8 

Design-S 350 

350 

650 x 650 x 20 

15,0 

Design-S 350 RF 

350 

650 x 650 x 20 

15,0 

Design-W/B/M 450 

450 

1030 x 690 x 20 

17,5 

Design-W/B/M 450 RF 

450 

1030 x 690 x 20 

17,5 

Design-W/B/M 600 

600 

1330 x 690 x 20 

23,0 

Design-W/B/M 600 RF 

600 

1330 x 690 x 20 

23,0 

Design S 600 

600 

1250 x 650 x 20 

23,0 

Design S 600 RF 

600 

1250 x 650 x 20 

23,0 

Design-W/B/M 750 

750 

1330 x 690 x 20 

23,0 

Design-W/B/M 750 RF 

750 

1330 x 690 x 20 

23,0 

Design S 750 

750 

1250 x 650 x 20 

23,0 

Design S 750 

750 

1250 x 650 x 20 

23,0 

Design-W/B/M 950 

950 

1630 x 690 x 20 

26,0 

Design-W/B/M 950 RF 

950 

1630 x 690 x 20 

26,0 

Design-W/B/M 1200 

1200 

1930 x 690 x 20 

29,0 

Design-W/B/M 1200 RF 

1200 

1930 x 690 x 20 

29,0 

model width  

545 mm 

power 
[Watt] 

W x H x D [mm] 

weight 

Model width  

545 mm 

power 
[Watt] 

W x H x D [mm] 

weight 

Design-W/B/M 351 

350 

1050 x 454 x 20 

14,0 

Design-W/B/M 351 RF 

350 

1050 x 454 x 20 

14,0 

Design-W/B/M 501 

500 

1350 x 454 x 20 

18,0 

Design-W/B/M 501 RF 

500 

1350 x 454 x 20 

18,0 

Design-W/B/M 651 

650 

1650 x 454 x 20 

22,0 

Design-W/B/M 651 RF 

650 

1650 x 454 x 20 

22,0 

Design-W/BM 851 

850 

1950 x 454 x 20 

26,0 

Design-W/BM 851 RF 

850 

1950 x 454 x 20 

26,0 

W = white | B = black | M= mokka |S = mirror 

RF

“: 

Units are supplied with preassembled radio receiver

 

 

 

GB 

Summary of Contents for ISP Design S 350

Page 1: ...ISP Design 350 1200 ISP Design S 350 750 Nr 911 360 661 Edition 02 17 Installation and technical manual ISP Design ISP DesignS Mirror withreceiver RF GB 2 3 ...

Page 2: ...ols In case the connection cable is damaged it has to be replaced by the manufacturer or someone commissioned by the manufacturer WARNING Do not use a switching oriented device like a timekeeper when operating this heater This could cause a change in the thermal adjustment which is potentially hazardous To keep the device from overheating do not put towels or clothing on top When using the heater ...

Page 3: ...lectrical connection must be carried out by a qualified electrician The panels are designed for wall mounting only Wall mounting only No ceiling mounting allowed The plate can be mounted horizontally or vertically Drill mounting holes as indicated in pic 1 horizontally or as in pic 2 vertically The pack contains 4 6 screws for the models ISP Design 600 S 600 till 1200 S750 ISP Design 501 till 851 ...

Page 4: ...h incl RF drill spacing holes A mm B mm C mm D mm ISP Design 350 ISP Design S 350 324 360 360 324 ISP Design 450 624 360 360 624 ISP Design 600 ISP Design S 600 624 A 2 312 360 360 624 D 2 312 ISP Design 750 ISP Design S 750 924 A 2 462 360 360 924 D 2 462 ISP Design 950 1224 A 2 612 360 360 1224 D 2 612 ISP Design 1200 1524 A 2 762 360 360 1524 D 2 762 all models with 454 mm width incl RF drill s...

Page 5: ...0 Design W B M 450 450 1030 x 690 x 20 17 5 Design W B M 450 RF 450 1030 x 690 x 20 17 5 Design W B M 600 600 1330 x 690 x 20 23 0 Design W B M 600 RF 600 1330 x 690 x 20 23 0 Design S 600 600 1250 x 650 x 20 23 0 Design S 600 RF 600 1250 x 650 x 20 23 0 Design W B M 750 750 1330 x 690 x 20 23 0 Design W B M 750 RF 750 1330 x 690 x 20 23 0 Design S 750 750 1250 x 650 x 20 23 0 Design S 750 750 125...

Page 6: ...ta s oft the receiver RF power supply 230 V 50 Hz 10 protection class II consumption 0 5 V switching capacity max 16 A 230 Veff Cos φ 1 radio frequency 868 MHz Norm EN 300 220 radio range up to 300 m outdoor indoor up to 30 m depending of structural factors and electromagnetic interference maximum number of recipients 8 units temperature range 5 C to 50 C dimensions 120 x 54 x 25 mm IP 44 IK 04 Sw...

Page 7: ...s 3 times the receiver button 2 The LED flashes 3 2 times for X2D 3 times for X3D Errors and technical modifications reserved Lucht LHZ Elektroheizung GmbH Co KG Reinhard Schmidt Str 1 09217 Burgstädt Fon 03724 66869 0 Fax 03724 66869 20 E mail info technotherm de TECHNOTHERM support Fon 49 0 911 93 78 32 10 GB ...

Page 8: ...8 Edition 02 17 Manual ISP Design web www technotherm de ...

Reviews: