iPOS4803 Microdrive EtherCAT Technical Reference
3.12 USB connection
3.12.1 USB connection
Figure 49
USB connection for iPOS4803P and iPOS4803PE
For iPOS4803P and iPOS4803PE drives, high-speed signals (USB DP, USB DM) must be routed as differential pairs,
with controlled impedance, microstrip or stripline.
Figure 50
USB connection for iPOS4803S
For the USB connection a standard USB cable is required. The drivers are found automatically in Windows 10 and the
device is identified as a COM port.
In Easy Motion studio, choose the following communication settings:
Figure 51
USB connection
Instead of COM1, choose the new COM value detected after the driver is installed.