Technosoft 2019
24
iPOS360x VX-CAN/CAT Technical Reference
3.7.3
24V Digital I/O Connection
Figure 3.13.
24V Digital NPN Inputs connection
Remarks:
1. The inputs are compatible with NPN type outputs (input must be pulled to GND to change its default state)
2. The length of the cables must be up to 30m, reducing the exposure to voltage surges in industrial environment.
3. The outputs are compatible with NPN type inputs (load is tied to V
LOG
, output pulls to GND when
active and is floating when inactive)
4. The maximum sink current is 0.5A continuous, up to 1A pulsed for less than 5 seconds