3.5.7
Motor connections
3.5.7.1
Brushless Motor connection
Figure 3.15.
Brushless motor connection
Remark:
In case J7 (Earth) is not present, connect the Shield (if present) to GND instead.
3.5.7.2
2-phase Step Motor connection
Figure 3.16.
2-phase step motor connection, one coil per phase
Figure 3.17.
2-phase step motor connection, two coils per phase
Remark:
In case J7 (Earth) is not present, connect the Shield (if present) to GND instead.