![Technomax FPP/3 Instructions Download Page 3](http://html.mh-extra.com/html/technomax/fpp-3/fpp-3_instructions_1070565003.webp)
6. RESETTING THE SAFE
ATTENTION! This operation permanently erases all stored fingerprints.
With the door open and the bolts indented, with a screwdriver, unscrew the screw of the battery
compartment and remove the 4 batteries,
Press and hold the red button programming until the end of the following procedure:
1 Insert the 4 batteries making sure to have respected the polarity insertion.
2 Wait until you hear three beeps are long and bolts protrude.
All fingerprints have been deleted and the safe returned in original condition (opening with any
fingerprint).
7. INSTALLING THE SAFE
It is necessary fixing the safe by means of the provided mounting holes. can use the brackets provide, which
are in common use, or in the case of special structures, seek advice from your local dealer for the choice of
the most suitable for dowels planner / need.