WL 2000-AIR QUALITY MONITOR 

Instructions manual 

 

FEATURES: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

x

 

Quartz clock  

x

 

12/24h time display 

x

 

Indoor temperature display in °C/°F  

x

 

Indoor humidity display in %RH  

x

 

Outdoor temperature display in °C/°F  

x

 

Air quality sensor for monitoring of indoor air quality  

x

 

Display of CO

2

 equivalent values and quality indicator 

x

 

Air quality alarm per LED   

x

 

Low battery indicator 

 

SETTING UP: 

1. 

Open the battery cover at the back of the transmitter and open 
the battery cover at the back of the air quality monitor. 

2. 

Checking the correct polarization, insert 2 x C, IEC LR14, 1.5V 
Alkaline batteries into the battery compartment of the outdoor 
transmitter and insert 2 x AA, LR06, 1.5V Alkaline batteries in 
the air quality monitor. Replace the cover. 

3. 

When the batteries are inserted, all the segments of the LCD 
will light up briefly. The monitor will receive data signal from the 
outdoor transmitter in a few seconds. 

4. 

Hold the SET key for 3 seconds to manually enter a time.  
(See manual settings.) 

 

Note:  

x

 

The equivalent CO

2  

ppm will only be displayed after 30 minutes. 

x

 

The air quality sensor will take up to 5 days after inserting 
battery to condition itself for the room it is placed. If the unit is 
placed into another room, there might be a reconditioning time 
of several days as well. 

x

 

Insert  the  holder  to  the  bottom  of  the  outdoor  transmitter  for 
table standing or insert it to the back of the transmitter for wall 
mounting purpose. 

x

 

Set the air quality monitor in a dry and shaded interior and 
away from sources of interference, such as televisions or metal 
plates. The transmitter should be mounted protected from rain 
and direct sunlight. 
 

INSTALLING AND REPLACING THE BATTERY IN THE AIR 
QUALITY MONITOR 

The outdoor transmitter uses 2 x AA, LR06, 1.5V batteries. 
The air quality monitor uses 2 x C, LR14, 1.5V batteries.  
To install and replace the batteries, please follow the steps below: 
 
1. 

Remove the cover at the back of the air quality monitor or the 
outdoor transmitter. Remove the old batteries and wait 2 
minutes before the next step. 

2. 

Insert batteries observing the correct polarity (see marking). 

3.  

Replace compartment cover. 

 
BATTERY CHANGE: 

It is recommended to replace the battery regularly to ensure optimum 
accuracy of the unit. 
 
 
 

 

Add device to MOBILE-ALERTS system 

(MOBILE ALERTS gateway needed, sold separately) 
 
Open the app, dashboard is displayed. Tap "Add new sensor" and 
scan the QR code on the back of the WL 2000. Then set a name for 
the sensor. To set a name, select the transmitter and then tap on the 
left area of the pencil icon in the upper right. 

 
Read measurements 

Now you can read the measurements on your mobile phone.

 

 

KEY FUNCTIONS: 

The Air Quality Monitor has 4 easy-to-use keys: 

 
 
 
 
 
 
 
 
 
 
 
 

SET key: 

x

 

Press and hold to enter the manual setting modes:12/24 hour 
time display, manual time setting,  ºC / ºF temperature display,  

x

 

Exit the manual setting mode 

 

+ key: 

x

 

Press to change values of all manual settings 

 

ALERT key: 

x

 

Press to set the air quality alert to ON / OFF 

 

MIN / MAX key: 

x

 

Press to view MIN and MAX temperature and humidity values  

 

LCD SCREEN 

 
 

 

 
 
 

 
 

MANUAL SETTINGS: 

The following manual settings can be done in the setting mode: 
1. 

12/24 hour time setting 

2. 

Time setting 

3. 

ºC / ºF temperature display setting 

 
Press and hold the SET button for about 3 second to enter the setting 
mode: 

 
12/24 HOUR TIME DISPLAY SETTING

 

x

 

“12hr” or “24hr” flashes in the LCD.

 (default 24hr) 

x

 

Press the 

+

 

key to select the “12hr” or “24hr” display mode.

 

x

 

Confirm with the 

SET

 key and enter the 

Manual time setting

 

MANUAL TIME SETTING 

To set the clock: 

x

 

The hour digits start flashing in the time display section. 

x

 

Use the 

+

 key to adjust the hours and then press 

SET 

key to go 

to the minute setting. 

x

 

The minute will be flashing. Press the 

+

 key to set the minutes. 

x

 

Confirm with the 

SET

 key and enter the 

°C/°F temperature 

setting

 

°C/°F TEMPERATURE UNIT SETTING 

The default temperature reading is set to °C (degree Celsius). To 
select °F (degree Fahrenheit): 
1. 

The “°C” will be flashing, use the 

+

 key to toggle between 

“°C” 

and “°F”.

 

2. 

Confirm with the 

SET

 key and

 exit the manual settings

 

Max./ Min. for the indoor/outdoor temperature and humidity 

Press 

MIN/MAX

 for displaying of max./min. of temperature and 

humidity. 
 

AIR QUALITY ALERT SETTING 

Press  the ALERT button to activate the air quality alert. The air 
quality alert OFF icon indicates that the alert is set off. No air quality 
OFF icon indicates that the alert is set on. 

 
Note: 

The LED Alert blinks, i

f the air quality alert has been set to “

ON

 and 

the 

Equivalent CO

2  

ppm

 

is higher than 1500ppm:

 

 

AIR QUALITY INDICATOR 

The air quality indicator is located on the bottom of the LCD. It 
changes from GREEN to RED by according to the equivalent CO

2  

ppm value.   
 
 
 
 
 
 
 
 
 
 
 
 
* The air quality value shown, after sensor conditioning, may differ 
 +/- 250 ppm.

 

 
Note: 

A 9-

level bar graph is used to indicate “GREEN” to “RED” air quality 

level in the surrounding environment: 
 

Levels 

Equivalent CO

2  

ppm 

GREEN (level 1) 

450 

 600ppm 

Level 2 

650 

 800ppm 

Level 3 

850 

 1000ppm 

Level 4 

1050 

 1200ppm 

Level 5 

1250 

 1500ppm 

Level 6 

1550 

 1800ppm 

Level 7 

1850 

 2100ppm 

Level 8 

2150 

 2400ppm 

RED (level 9) 

≥ 2450ppm

 

 
Troubleshooting 

When no sensor readings are displayed in the app, check if the green 
LED on the gateway is permanently lit. If not, please check if: 
- The gateway is properly connected to the power plug, the router and 
is turned on. 
- Restart the station by removing the batteries for a minute and 
reinserting, to restart the device. 
- Your phone is connected to the internet. 
- The signal is weakened by thick walls and ceilings. Put the device in 
operation near the gateway and then locate a suitable location. 

 

More information and detailed instructions can be found in the app at 

“Info” or at 

www.mobile-alerts.eu

 

 

Summary of the Declaration of Conformity:  We hereby declare that 
this device does comply with the requirements of RED Directive 
2014/53/EU. The declaration of Conformity can be found at: 

www.mobile-alerts.eu/technoline/doc

 

 

SPECIFICATIONS

Recommended temperature range:  
+5ºC to +40ºC / +41ºF to 104ºF 

Temperature measuring range: 

Indoor:  

 

-9.5ºC to +59.5ºC with 0.5ºC resolution /  
14.0ºF to +139.5ºF with 0.5ºF resolution 
(OFL displayed if outside this range. In degree F 
display, OFL will displayed when over 99.9ºF) 

Outdoor:    

-

 

39.9ºC to +59.9ºC with 0.1ºC resolution /  

-39.8ºF to +139.8ºF with 0.2ºF resolution 
(OFL displayed if outside this range. In degree F 
display, OFL will displayed when over 99.9ºF) 

Relative humidity measuring range: 

Indoor:     

20% to 95% with 1% resolution 

(display “

- -

“ if 

temperature is OFL, except when the temperature is 

100ºF to 139.8ºF; display “19%” if < 20% and “96%” 

if > 95%) 

Equivalent CO

2  

ppm measuring range: 

450ppm to 3950ppm with 50ppm resolution (display OFL > 3950ppm)

 

Measuring intervals: 

Indoor temperature checking interval: 

every 16 seconds   

Indoor humidity checking interval: 

every 16 seconds 

Air quality level checking interval: 

every 3 minutes   

Transmission: 

Transmission range:  

100m / 330 feet 

Transmission frequency:  

868 MHz 

Maximum transmission power:  

13 dBm 

Power consumption: 

  

 

2 x C, IEC LR14, 1.5V 

Dimensions

 (L x W x H):    

135.4 x 35.3 x 153.9 mm 

 
Trouble shooting 

Keep in mind that the outdoor transmitter only has the optimal 
transmission range in open area with no obstructions. Each 
obstruction between the transmitter and the station (roof, walls, floors, 
ceilings, thick trees, etc.) will effectively cut the transmission range in 
half. 

 

Precautions 

x

 

This main unit is intended to be used only indoors. 

x

 

Do not subject the unit to excessive force or shock. 

x

 

Do not expose the unit to extreme temperatures, direct sunlight, 
dust or humidity. 

x

 

Do not immerse in water. 

x

 

Avoid contact with any corrosive materials.   

x

 

Do not dispose this unit in a fire as it may explode. 

x

 

Do not open the inner back case or tamper with any components 
of this unit. 

 
Batteries safety warnings 

x

 

Please read all instructions carefully before use. 

x

 

Use only alkaline batteries, not rechargeable batteries. 

x

 

Install batteries correctly by matching the polarities (+/-). 

x

 

Always replace a complete set of batteries. 

x

 

Never mix used and new batteries. 

x

 

Remove exhausted batteries immediately. 

x

 

Remove batteries when not in use. 

x

 

Do not recharge and do not dispose of batteries in fire as the 
batteries may explode. 

x

 

Ensure batteries are stored away from metal objects as contact 
may cause a short circuit. 

x

 

Avoid exposing batteries to extreme temperature or humidity or 
direct sunlight. 

x

 

Keep all batteries out of reach from children. They are a choking 
hazard. 

 
Use the product only for its intended purpose! 

 

Old batteries do not belong to domestic waste because they could cause 

damages of health and environment. Return used batteries  to your 
dealer and collection points. As end user you are committed by 
law to bring back used batteries to distributors or other collecting 
points! 

 

Function keys 

LCD display 

 

Battery 

compartment 

SET key 

MIN / MAX key 

+ key 

ALERT key 

Air quality alert 

OFF icon 

Low battery icon (outdoor)

 

Indoor 

temperature 

in ºC/ºF 

Equivalent CO

2  

ppm / seconds 
display 

Air quality 
 indicator 

Bar graph 

Equivalent CO

2  

ppm (parts per 
million) value* 

Air quality 
 indicator

 

Time 

Outdoor 

temperature in 

ºC/ºF 

Low battery icon 
(indoor) 

 

Reception 
icon

 

Indoor 
humidity in 
%RH 

MIN / MAX icons 

Reviews: