RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 7.18
7.12.
MOTOR GUARD DISASSEMBLY
Figure7.12-1
1.
Bring the machine at the maximum
elevation.
2.
Turn off the machine and unplug the mains
lead from the wall outlet.
3.
Back off the 2 screws
(a)
on either side of the
machine through a ¼ turn, using a medium
flat-blade screwdriver.
4.
Back off the 3 screws
(b)
through a ¼ turn,
using a medium flat-blade screwdriver.
5.
Remove the top part of the motor guard.
Figure7.12-2
6.
Disconnect the fan cable and the limit switch
connectors, highlited in the figure.
Figure7.12-3
7.
Back off the 5 screws
(c)
using a 4mm
hexagonal wrench.