Technogym BIOCIRCUIT Manual Download Page 5

BIOCIRCUIT - BIOCIRCUIT FREE Pre-Installation Requirements
Rev. 6.0

- 5 -

PIR-00063-EN- Uncontrolled copy if printed

This document contains proprietary information that is covered by copyright. All rights re-

served. No part of this document may be circulated, copied, reproduced or translated into 

another language without the prior written consent of Technogym.

Additional information may be included in the After Sales technical documents, available 

in the Technogym 

Service

Portal.

The information contained in this document may be changed without prior notification. For 

updates, please refer to the Technogym 

Service 

Portal.

Technogym® is a trademark owned by Technogym S.p.A.

Document uncontrolled when printed.

Summary of Contents for BIOCIRCUIT

Page 1: ...BIOCIRCUIT BIOCIRCUIT FREE Pre Installation Requirements Rev 6 0 Date 17 09 2021 Document Code PIR 00063 EN...

Page 2: ......

Page 3: ...15 4 3 ELECTRICAL CONNECTION 15 4 4 POSITION OF THE PRODUCT SOCKET 16 5 BIOCIRCUIT BIOCIRCUIT FREE NETWORK REQUIREMENTS 21 5 1 BIOCIRCUIT NETWORK CONFIGURATION FORBIDDEN MIXED CONFIGURA TIONS 21 5 2 B...

Page 4: ...5 4 4 PROXY 27 5 4 5 NETWORK BANDWIDTH REQUIREMENTS 27 5 5 SPECIFIC REQUIREMENTS FOR UNITY SELF OF BIOCIRCUIT 28 6 ACKNOWLEDGEMENT AND ACCEPTANCE 29 7 LIST OF CHANGES FOR MANUAL VERSION 31 7 1 REVISIO...

Page 5: ...copied reproduced or translated into another language without the prior written consent of Technogym Additional information may be included in the After Sales technical documents available in the Tec...

Page 6: ...BIOCIRCUIT BIOCIRCUIT FREE Pre Installation Requirements Rev 6 0 6 PIR 00063 EN Uncontrolled copy if printed Blank page...

Page 7: ...WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may re sult in...

Page 8: ...Blank page BIOCIRCUIT BIOCIRCUIT FREE Pre Installation Requirements Rev 6 0 8 PIR 00063 EN Uncontrolled copy if printed...

Page 9: ...TALLATION During the network design and preparation phases Technogym requests to be put in touch with the technicians of the company performing the work in order to obtain and provide technical infor...

Page 10: ...BIOCIRCUIT BIOCIRCUIT FREE Pre Installation Requirements Rev 6 0 10 PIR 00063 EN Uncontrolled copy if printed Blank page...

Page 11: ...Rev 6 0 11 PIR 00063 EN Uncontrolled copy if printed 3 DISPLAY 3 1 BIOSTRENGTH LINE 3 1 1 UNITY MINI Equipment of BIOSTRENGTH LINE may be fitted with UNITY MINI Display Fig 1 3 1 2 10 DISPLAY Equipmen...

Page 12: ...SELF NOT NECESSARY FOR BIOCIRCUIT FREE A Unity Self is NOT mandatory for a Biocircuit Free format but it is strongly recommended to have at least 1 per location to let end users manage their prescribe...

Page 13: ...tage 100 240Vac 50 60Hz Tab 1 Power Supply MAXIMUM ABSORPTION VALUES Power Supply 100 240Vac 50 60Hz Max Absorption 110V Max Absorption 220V BIOSTRENGTH LINE except LEG PRESS 12A 6A LEG PRESS 20A 10A...

Page 14: ...PRESS Power Supply 220 Vac RECOMMENDED a C10 circuit breaker for each LEG PRESS Tab 4 Useful Guidelines for circuit breakers BIOSTRENGTH LINE TECHNICAL CHARACTERISTICS Motor peak power 2kW 6kW in Leg...

Page 15: ...ons Check the mains power supply specifications on the identification label on the label affixed close to the main switch The wall socket must be located in a place where the plugging and unplugging c...

Page 16: ...PRODUCT SOCKET The Chest Press Shoulder Press Low Row Vertical traction Lower Back and Total Abdominal machines have the product socket positioned on the front side as shown below Fig 5 Example pictur...

Page 17: ...BIOCIRCUIT BIOCIRCUIT FREE Pre Installation Requirements Rev 6 0 17 PIR 00063 EN Uncontrolled copy if printed Fig 7 Leg Press Left Side Fig 8 Bike...

Page 18: ...BIOCIRCUIT BIOCIRCUIT FREE Pre Installation Requirements Rev 6 0 18 PIR 00063 EN Uncontrolled copy if printed Fig 9 Synchro Fig 10 Run...

Page 19: ...BIOCIRCUIT BIOCIRCUIT FREE Pre Installation Requirements Rev 6 0 19 PIR 00063 EN Uncontrolled copy if printed Fig 11 Unity Self...

Page 20: ...BIOCIRCUIT BIOCIRCUIT FREE Pre Installation Requirements Rev 6 0 20 PIR 00063 EN Uncontrolled copy if printed Blank Page...

Page 21: ...UIT if machines of BIOCIRCUIT are connected to a data network both via wireless and via ethernet cable mixed configuration Therefore you must have all BIOCIRCUIT equipment connected to a data network...

Page 22: ...tion Requirements Rev 6 0 22 PIR 00063 EN Uncontrolled copy if printed 5 2 2 Correct wireless network architecture Field of Application Biocircuit Fig 13 5 2 3 Correct complex network architecture man...

Page 23: ...IRCUIT FREE Pre Installation Requirements Rev 6 0 23 PIR 00063 EN Uncontrolled copy if printed 5 2 4 Forbidden network architecture that causes local network latency Example 1 Field of Application Bio...

Page 24: ...le 2 Field of Application Biocircuit Fig 15 5 3 ROUTER WITH 4G FAILOVER IN CASE OF UNSTABLE INTERNET CONNECTION Field of Application Biocircuit Technogym strongly recommends to use a ROUTER WITH 4G FA...

Page 25: ...e the correct functioning of BIOCIRCUIT if UNITY SELF is connected to a data network via wireless Ethernet Cabled Network Requirements _ Category 5e 6 UTP Ethernet cables with RJ45 patch _ Switch with...

Page 26: ...ME at least three days Wi Fi Auto Channel disabled set on the best fixed channel for that structure SESSION TIMEOUT disabled Typically achieved setting the timeout 0 For more details about your chosen...

Page 27: ...llness cn Tab 9 Only for China Moreover It shall be possible to download tar gz and tar packets 5 4 4 Proxy Proxy not managed 5 4 5 Network bandwidth requirements The below table illustrates the minim...

Page 28: ...printed 5 5 SPECIFIC REQUIREMENTS FOR UNITY SELF OF BIOCIRCUIT As defined above UNITY SELF MUST BE CONNECTED TO A DATA NETWORK BY ETHERNET CABLE Compliant UNITY SELF starting from UNITY SELF ARTIS 20...

Page 29: ...REE Pre Installation Requirements Rev 6 0 29 PIR 00063 EN Uncontrolled copy if printed 6 ACKNOWLEDGEMENT AND ACCEPTANCE Date ____________________________________________ Acknowledged and accepted ____...

Page 30: ...BIOCIRCUIT BIOCIRCUIT FREE Pre Installation Requirements Rev 6 0 30 PIR 00063 EN Uncontrolled copy if printed Blank page...

Page 31: ...3 0 Changed paragraph 5 2 Broadcast Network specified the mandatory use of equipment connect ed to a data network or via wireless or via cable Changed paragraph 5 3 Access Point specified the use of o...

Page 32: ...the reference to the new display 10 New paragraph RECOMMENDATION RCD SWITCH TYPE F 7 6 REVISION 6 0 Modified 5 4 2 Wi Fi Network the Wi Fi Auto Channel must be disabled BIOCIRCUIT BIOCIRCUIT FREE Pre...