background image

22

BIKE ARTIS

ROUTINE MAINTENANCE 

The product should always be kept clean and free of dust, in compliance with common health and hygiene standards.

To clean the display , proceed as follows.
-  Turn off the product by pressing the main switch to the “0” position.
-  Take the product’s power plug out of the wall socket.
-  Clean the display using a damp (not wet) cloth.

Clean the entire product once a week.
-  Turn off the product by pressing the main switch to the “0” position.
-  Take the product’s power plug out of the wall socket.
-  Clean outer parts with a damp sponge.

Do not use chemical products or solvents.

 Warnings

Do not press too hard on the display or the illustrations and instructions on the labels.
The safety of the product is assured only on the condition that it is carefully inspected every two weeks for any signs of damage and/or wear. 
Replace defective or worn components immediately, or remove the product from service.

For maintenance actions not described in this manual, call in the Technogym Technical Service.

Summary of Contents for BIKE ARTIS

Page 1: ...BIKE ARTIS USER MANUAL...

Page 2: ...ing the heart rate monitor 11 Technical characteristics 13 Safety devices 14 Place of usage 15 Moving the product 16 Levelling 17 Electrical connection 18 Other connections 20 Turning on and off 21 Ro...

Page 3: ...following precautions Theproductshouldneverbeleftunattendedwhenpluggedin Unplugtheproductfromthepowersocketwhennotinuse beforecleaningit andbeforeinstalling or removing electrical parts Do not allow c...

Page 4: ...rop or insert any object into any opening To disconnect power turn all controls to the off position then remove the plug from the outlet SAVE THESE INSTRUCTIONS Warnings Do not connect a device with l...

Page 5: ...rkout clothing and shoes during training do not wear garments that block perspiration do not wear loose clothing Tie long hair back Keep garments or towels away from moving parts When using the produc...

Page 6: ...on debris resulting from any construction activities in the area where the product is used rust or corrosion as a result of the product s location alterations or modifications without Technogym s writ...

Page 7: ...C B A G E F D IDENTIFICATION OF THE MANUFACTURER AND THE PRODUCT A Manufacturer s name and address B Place of manufacture C Description of product D Electrical specifications E Tells you to consult th...

Page 8: ...itoring Fast Track Control E They allow users to change the level of intensity of the exercise without removing their hands from the handlebar Saddle F With adjustable height Pedals G With adjustable...

Page 9: ...legs are fully extended when the pedals are in the lower position On the saddle lean your torso forwards keeping your back straight then rest your hands on the ends of the handlebar your arms will be...

Page 10: ...ised to save it in the training program Warning If the saddle position is too high or too low this could result in incorrect leg movement which may cause pains in various parts of the body To adjust t...

Page 11: ...tacttheTechnical Support Service Warnings During a workout it is very important that your heart rate never goes above 90 ofyourmaximumrate unlessyouareanathleteengagedincompetitive sport Thesolefuncti...

Page 12: ...rateof70 to90 thecardiocirculatory component prevails For example if someone aged 30 wants to burn off fat the heart rate during exercise should be kept to between 112 60 and 131 70 if he or she wants...

Page 13: ...s power input 160 VA max Fuses 2 x 3 15A F Braking power 70 rpm 40 500 W 10 Time 0 999 min 1 Distance 0 99 99 km 5 0 99 99 mls 5 Protection grade IP 20 Electric isolation class Class I Adjustable brak...

Page 14: ...tecttheelectricalpartsoftheproduct Whenthecurrentreaches an excessive value the fuses melt thus protecting the internal electronics Open panel D to reach the fuses put a finger in the hole and pull Th...

Page 15: ...ng conditions An empty space at least 60 cm wide all around every product A flat stable and vibration free surface that is capable of supporting the weight of both the product and the user The product...

Page 16: ...tip over Theproducthasfixedfrontwheels Tomovetheequipment liftitupslightly as shown in the illustration and push it forwards and backwards If wheels cannot be used on the floor move the equipment wit...

Page 17: ...tion correctly the product must be level Adjust the feet as shown in the diagram in order to level the product Loosen the lock nut B Screw the front feet A in or out until the frame is in a stable pos...

Page 18: ...A to reach the label and connector put a finger in the hole and pull Warnings The wall socket must be located in a place where the plugging and unplugging can be done easily and safely When plugging...

Page 19: ...cshock Theproductisequippedwithacordhavinganequipment groundingconductorandagroundingplug Theplugmustbepluggedintoanappropriate outlet that is properly installed and grounded in accordance with all lo...

Page 20: ...el D putafingerinthespecificholeandpull After connection close panel D putting the cables through the slot Use an RF coaxial cable to connect the antenna with an F type connector for the product The w...

Page 21: ...the product off after exercising when it is in stand by If you do not expect to use the product for some time turn it off at the main switch and take the power plug out of the wall socket Warnings Th...

Page 22: ...product by pressing the main switch to the 0 position Take the product s power plug out of the wall socket Clean outer parts with a damp sponge Do not use chemical products or solvents Warnings Do not...

Page 23: ...rication jobs must be performed by the Technogym Technical Support Service Before servicing turn off the product by moving the switch to the 0 position and take the power plug out of the socket Everys...

Page 24: ...E You are advised to check for play on the tube periodically as it may cause vibrations and noise Adjust the play by turning the two screws undo the screw A turn the 2 screws B with an Allen wrench ch...

Page 25: ...the wall socket If no more of the supplied fuses are available use certified fuses with identical electrical specifications 3 15A F for the replacement Open the panel A to reach the fuses put a finge...

Page 26: ...gging in another appliance that you know works Power supply cable damaged Contact the Technogym Technical Support Service The power supply cable is not correctly inserted Check the connection Burnt ou...

Page 27: ...ce provides telephone consultation information about which services are covered by the warranty and which must be paid for on site servicing supply of original spare parts WhenyoucontacttheTechnogymTe...

Page 28: ...on regulations in force by firms specialised in urban and environmental hygiene Waste deriving from electrical and electronic equipment must not be disposed of as urban waste A specific disposal syste...

Page 29: ...Bike Artis_en_AA 0SM01148...

Reviews: